Optimus+ Industrial Sound Level Meter vs LA-4441A
Every specification Cirrus Research and Ono Sokki publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.
| Specification | Optimus+ Industrial Sound Level MeterCirrus Research | LA-4441AOno Sokki |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| IEC 61672-1 class | Class 1 | Class 1 |
| Standards (differs) | IEC 61672-1:2013 class 1 or class 2, IEC 61672-1:2002 class 1 or class 2 group X, IEC 60651:2001 type 1 or type 2, IEC 60804:2000 type 1 or type 2, IEC 61252:1993, ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), ANSI S1.25:1991, IEC 61260:1996 and ANSI S1.11-2004 (octave band models), DIN 45657:2005-03 | IEC 61672-1:2013 class 1, JIS C 1509-1:2017 class 1, JIS C 1516:2020 class 1 |
| Pattern approvals (differs) | PTB (DIN EN 61672), optional, LNE (IEC 61672), optional, Leq and octave band models | — |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | 20 to 140 dB, single RMS range | A: 27 to 135 dB; C: 30 to 135 dB; Z: 35 to 135 dB |
| Linearity range (differs) | — | 100 dB (wide range), 80 dB (normal range) |
| Frequency range (differs) | 31.5 Hz to 16 kHz (1:1 octave bands, C models) | 10 Hz to 20 kHz |
| Frequency weightings | A, C, Z | A, C, Z |
| Time weightings | F, S, I | F, S, I |
| Simultaneous weightings (differs) | Yes | — |
| Parameters (differs) | LXY (X = A, C, Z; Y = F, S, I), LXYmax, LXYmin, LXeq, LCpeak, LZpeak, LApeak, LCeq-LAeq, LXE, LAIeq, LAVG, Dose and estimated dose, NR/NC (C models) | Lp, Leq, LE, Lmax, Lmin, Lpeak, LN (Lhigh, L5, L10, L50, L90, L95, Llow, Lave) |
| Dosimetry (differs) | Yes | — |
| Exchange rates (differs) | 3 dB, 4 dB, 5 dB | — |
| Analysis | ||
| Octave bands (differs) | 1/1 | None |
| Audio recording (differs) | Yes | No |
| Logging and data | ||
| Shortest logging interval (differs) | 10 ms | 1 ms (Lp record memory: 1, 2, 5 or 10 ms) |
| Memory (differs) | 8 GB standard; 32 GB factory option | Lp record 1000 addresses x 200 blocks; Leq 1000 addresses x 200 blocks; total values 100 addresses x 200 blocks; 9 condition memories |
| Hardware | ||
| Microphone (differs) | class 1: MK:224 or MK:229 1/2" pre-polarised; class 2: MK:216 pre-polarised | MI-1235 1/2" back-electret condenser, -29 dB nominal sensitivity, with MI-3111 preamplifier |
| Detachable preamplifier | Yes | Yes |
| Display (differs) | high-resolution colour display with ambient light sensor and illuminated keypad | 124 x 64 dot LCD with LED backlight |
| Battery (differs) | 4 x AA alkaline or lithium | 2 x AA (alkaline); optional PB-7090 AC adapter |
| Battery life (differs) | 12 h | 8 h |
| External power (differs) | 5 to 15 V DC via ZL:171 cable | — |
| Weight (differs) | 300 g | 360 g |
| Dimensions (mm) (differs) | 283 x 65 x 30 | 78 x 263 x 47 |
| Operating temperature (°C) | -10 to 50 | -10 to 50 |
| Connectivity and software | ||
| Connectivity (differs) | USB type B, Bluetooth Low Energy, AC/DC output (ZL:174 cable) | USB 2.0 Full Speed (virtual COM port), RS-232C, AC output, DC output, external control input |
| Remote control (differs) | MyCirrus mobile apps (iOS, Android) via Bluetooth | — |
| Software (differs) | NoiseTools, MyCirrus app | — |
The instruments on their own
- Optimus+ Industrial Sound Level Meter — full record, sources and owner reviews
- LA-4441A — full record, sources and owner reviews
Other comparisons
Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.