Compare instruments
Up to 4 instruments of the same type, every published specification side by side. Rows where the values differ are tinted. A blank cell means the manufacturer does not publish that value.
Comparing 2 handheld sound level meters. Back to the category table.
| Specification | Aihua AWA5662Hangzhou Aihua Instruments | Optimus+ Environmental Sound Level MeterCirrus Research |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| IEC 61672-1 class | Class 1 | Class 1 |
| Standards (differs) | IEC 61672-1:2013 class 1, IEC 61260-1:2014 class 1, IEC 61252:2025 (AWA5662-1) | IEC 61672-1:2013 class 1 or class 2, IEC 61260 and ANSI S1.11-2004 (1:1 and 1:3 octave filters), IEC 60651, IEC 60804, ANSI S1.4, ANSI S1.43, DIN 45657 |
| Pattern approvals (differs) | — | PTB (class 1), LNE (class 1) |
| Recommended calibration interval (differs) | — | 12 months |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | 25 to 140 dB(A), 115 dB linear range without range switching; 16 to 131 dB(A) with low-level microphone; 48 to 163 dB(A) or 62 to 174 dB(A) with high-level microphones | 20 to 140 dB, single range |
| Frequency range (differs) | 10 Hz to 20 kHz | 6.3 Hz to 20 kHz (1:3 octave bands measured; 12.5 Hz to 20 kHz displayed) |
| Frequency weightings | A, C, Z | A, C, Z |
| Time weightings | F, S, I | F, S, I |
| Simultaneous weightings (differs) | — | Yes |
| Parameters (differs) | Lp, Leq,T, Lmax, Lmin, LE, Lpeak, E, TWA, Lex,8h, LCpeak, LZpeak, LAVG, DOSE, NLApeak, Ln, SD | LXeq, LXYmax, LXYmin, LCpeak, LZpeak, LXE, Ln statistics, Lden, Leq LF (20 to 200 Hz), tonal noise detection (C models) |
| Dosimetry (differs) | Yes | — |
| Analysis | ||
| Octave bands | 1/1 and 1/3 | 1/1 and 1/3 |
| Octave band filter class (differs) | class 1 | — |
| Audio recording | Yes | Yes |
| Logging and data | ||
| Shortest logging interval (differs) | — | 10 ms |
| Memory (differs) | 4 GB internal (not on AWA5662-0), TF card up to 64 GB optional | 8 GB standard; 32 GB factory option |
| Hardware | ||
| Microphone (differs) | AWA14425 standard; AWA14411 low-level; AWA14521 and AWA14434 high-level | class 1: MK:224 1/2" pre-polarised; class 2: MK:216 pre-polarised |
| Detachable preamplifier (differs) | — | Yes |
| Outdoor microphone kit (differs) | — | Outdoor Environmental Noise Kit (CK:67x/68x) with MK:172 outdoor microphone |
| Display (differs) | 2.4 inch colour, 240 x 320 | high-resolution OLED with ambient light sensor and illuminated keypad |
| Battery (differs) | 4 x LR6 (AA) alkaline | 4 x AA alkaline or lithium |
| Battery life (differs) | — | 12 h |
| External power (differs) | 5 V external supply | 5 to 15 V DC via ZL:171 cable |
| Weight (differs) | 340 g | 300 g |
| Dimensions (mm) (differs) | 250 x 76 x 33 | 283 x 65 x 30 |
| Operating temperature (°C) (differs) | -20 to 60 | -10 to 50 |
| Connectivity and software | ||
| Connectivity (differs) | USB, AC output, DC output, I/O | USB type B, Bluetooth Low Energy, AC/DC output, GPS (GPS model) |
| Remote control (differs) | — | MyCirrus mobile apps via Bluetooth; remote access via Outdoor Kit modem |
| Software (differs) | — | NoiseTools, MyCirrus app |