| Specification | Aihua AWA6292Hangzhou Aihua Instruments | CESVA SC250CESVA |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| IEC 61672-1 class | Class 1 | Class 1 |
| Standards (differs) | IEC 61672-1:2013 class 1, IEC 61260-1:2014 class 1, IEC 61252:2025 | IEC 61672-1:2013 class 1, EN 61672-1:2013 class 1, ANSI S1.4:2014 part 1 class 1, ANSI S1.43-1997 (R2007) class 1, IEC 61260-1:2014 class 1, EN 61260-1:2014 class 1, ANSI S1.11-2004 (R2009) class 1, OIML R 58:1998, OIML R 88:1998, OIML R 130:2001, DIN 45657:2014 (Taktmaximalpegel), IEC 61010-1:2010 A1:2016 / EN 61010-1:2010 A1:2019 |
| Pattern approvals (differs) | — | Spain (type examination 14/09/2021; additionals 24/02/2022, 18/04/2023, 04/06/2024), Portugal (30/03/2022), Czech Republic (22/06/2022), Switzerland (07/12/2022) |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | 20 to 143 dB(A); 123 dB linear dynamic range | Single range, 16.5 dB(A) to 140.1 dB(C) peak |
| Frequency range (differs) | 10 Hz to 20 kHz | — |
| Frequency weightings (differs) | A, C, Z, U | — |
| Time weightings (differs) | F, S, I | — |
| Parameters (differs) | Lxyp, Lxeq,T, Lxeq,t, Lxmax, Lxmin, LxN (N = 5, 10, 50, 90, 95), SD, SEL, Lxpeak | F1, F2 and F3 user-selected functions, NC and NR curve evaluation, pass / not pass against an adjustable threshold on F1 |
| Analysis | ||
| Octave bands | 1/1 and 1/3 | 1/1 and 1/3 |
| Octave band filter class (differs) | class 1 | 1/1 octave 8 Hz to 16 kHz; 1/3 octave 6.3 Hz to 20 kHz (optional module) |
| FFT (differs) | Optional module (lines not stated) | — |
| Reverberation time (differs) | Yes | — |
| Speech intelligibility (differs) | STI (type not stated) | — |
| Logging and data | ||
| Memory (differs) | 16 GB internal plus TF card up to 64 GB | Built in; recordings and final results saved as CSV, with a log of date, sensitivity and firmware changes |
| Hardware | ||
| Microphone (differs) | AWA14425 | — |
| Display (differs) | 4.3 inch capacitive touch screen | 3.5 inch capacitive colour touch screen |
| Battery (differs) | 10,000 mAh lithium | — |
| External power (differs) | 9 V DC, 20 W fast charging | — |
| Dimensions (mm) (differs) | 288 x 95 x 40 | — |
| IP rating (differs) | IP65 | — |
| Operating temperature (°C) (differs) | -20 to 60 | — |
| Connectivity and software | ||
| Connectivity (differs) | USB, 4G, WiFi, Bluetooth, Serial port, AC output, DC output, I/O | USB-C, Bluetooth, WiFi (CESVACloud, firmware updates, module activation) |
| Remote control (differs) | Mobile app | — |
| Software (differs) | — | CESVA Lab, Result Merging Tools (SE003), SC250 Link (Android) |