Skip to content
soundlevelmeter.review

Compare instruments

Up to 4 instruments of the same type, every published specification side by side. Rows where the values differ are tinted. A blank cell means the manufacturer does not publish that value.

Comparing 2 handheld sound level meters. Back to the category table.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationBedrock Elite i9BedrockNovaPulsar Instruments
StatusCurrentCurrent
Verified on
Manufacturer list priceGBP 1,100
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1 class 1, ANSI S1.4 type 1, IEC 61260 class 0, ISO 3382 (RT60), IEC 60268-16 rev. 4 (STIPA, Full STI), ISO 717 and ASTM E413 (Rw, STC)IEC 61672-1:2013 class 1 or class 2, group X, IEC 61672-2:2013, IEC 60651:2001 type 1 I or type 2 I, IEC 60804:2000 type 1 or type 2, IEC 61252:1993, ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), ANSI S1.25:1991, IEC 61260 and ANSI S1.11-2004 (1/1 octave filters)
Recommended calibration interval (differs)—12 months
Measurement
Channels (differs)—1
Measurement range (differs)20 to 130 dB(A) full range with the standard 50 mV/Pa microphone; 27 to 139 dB(A) with the optional PMP20 microphone20 to 140 dB RMS, single range
Linearity range (differs)> 110 dB dynamic range—
Peak range (differs)Peak C 42 to 140 dB; Peak Z 55 to 144 dB (with PMP20)up to 143 dB
Frequency range (differs)20 Hz to 16 kHz—
Frequency weightingsA, C, ZA, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightingsYesYes
Parameters (differs)Leq, Lmax, Lmin, Lpeak, L1 to L99, RT60 (EDT, T20, T30), D, R', DnT, L'nT, NR/NC/PNC/NCB/RC curves, THD+NLxy, Lxy max/min, Lxeq, LCpeak, LZpeak, LApeak, LCeq-LAeq, LxE, LAIeq, Ln (14 values), TWA, Dose %, estimated Dose %
Dosimetry (differs)—Yes
Exchange rates (differs)—3 dB, 4 dB, 5 dB
Analysis
Octave bands (differs)1/1 and 1/31/1
Octave band filter class (differs)class 0 (IEC 61260); 1/6 and 1/12 octave also availableIEC 61260 and ANSI S1.11-2004, 31.5 Hz to 16 kHz (Models 45/46)
FFT (differs)32768 lines—
Reverberation time (differs)YesNo
Building acoustics (differs)YesNo
Speech intelligibility (differs)STIPA and Full STI—
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)0.1 s10 ms (time history); periodic 1 min to 1 h and Lden
Memory (differs)16 GB internal4 GB removable memory card
Hardware
Microphone (differs)1/2" free-field IEC 61094-4 WS2F, XLR 48 V phantom, 50 mV/Pa; optional 1/4" free-field1/2" prepolarised PM1 (class 1) or PM2 (class 2); PA40 removable preamplifier
Detachable preamplifierYesYes
Outdoor microphone kit (differs)—WK3-N outdoor kit with PM172 outdoor microphone
Display (differs)3.2" colour LCD touch screenOLED with ambient light sensor (product description says TFT)
Battery (differs)NiMH pack, 4.8 V, 2500 mAh6 x AA; external 5 to 15 V DC via I/O socket
Battery life (differs)4 h30 h
Weight (differs)530 g440 g
Dimensions (mm) (differs)210 x 85 x 55 (excluding microphone)280 x 80 x 42 (with preamplifier and microphone)
Operating temperature (°C) (differs)5 to 35-10 to 50
Connectivity and software
Connectivity (differs)USB-CUSB 2.0 Mini-B, 3.5 mm AC output, multipin I/O (AC and DC output)
Remote control (differs)remote display via USB-C—
Software (differs)Bedrock Elite Analyzer, Bedrock StudioAnalyzerPlus
Latest firmware (differs)3.6.4—

Change the selection

Choose up to 4 instruments of the same type. Instruments are grouped by brand; the type is shown after the model name.

Compare sound level meters | soundlevelmeter.review