Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationCEL-620CasellaNovaPulsar Instruments
StatusCurrentCurrent
Verified on
Manufacturer list priceGBP 1,100
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672:2013 class 1 or class 2, ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), IEC 61260 class 1 (B models), ANSI S1.11-2004 (B models)IEC 61672-1:2013 class 1 or class 2, group X, IEC 61672-2:2013, IEC 60651:2001 type 1 I or type 2 I, IEC 60804:2000 type 1 or type 2, IEC 61252:1993, ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), ANSI S1.25:1991, IEC 61260 and ANSI S1.11-2004 (1/1 octave filters)
Recommended calibration interval (differs)—12 months
Measurement
Channels11
Measurement range20 to 140 dB RMS, single range20 to 140 dB RMS, single range
Peak range (differs)up to 143.0 dBup to 143 dB
Frequency weightingsA, C, ZA, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightingsYesYes
Parameters (differs)LXY, LXYmax, LXYmin, LXeq, LXpeak, Lavg, LC-LA, LXIeq, LTM3, LTM5, LAELxy, Lxy max/min, Lxeq, LCpeak, LZpeak, LApeak, LCeq-LAeq, LxE, LAIeq, Ln (14 values), TWA, Dose %, estimated Dose %
Dosimetry (differs)NoYes
Exchange rates3 dB, 4 dB, 5 dB3 dB, 4 dB, 5 dB
Analysis
Octave bands1/11/1
Octave band filter class (differs)class 1 (IEC 61260), 11 bands 16 Hz to 16 kHz (B models)IEC 61260 and ANSI S1.11-2004, 31.5 Hz to 16 kHz (Models 45/46)
Reverberation timeNoNo
Building acousticsNoNo
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)1 s10 ms (time history); periodic 1 min to 1 h and Lden
Memory (differs)999 runs of up to 24 h; 33 h of audio notes; about 1 year at 1 s interval4 GB removable memory card
Hardware
Microphone (differs)1/2" CEL-251 (class 1) or CEL-252 (class 2)1/2" prepolarised PM1 (class 1) or PM2 (class 2); PA40 removable preamplifier
Detachable preamplifierYesYes
Outdoor microphone kit (differs)—WK3-N outdoor kit with PM172 outdoor microphone
Display (differs)320 x 240 colour TFT, backlitOLED with ambient light sensor (product description says TFT)
Battery (differs)3 x AA alkaline or rechargeable; external 9 to 14 V DC6 x AA; external 5 to 15 V DC via I/O socket
Battery life (differs)20 h30 h
Weight (differs)295 g440 g
Dimensions (mm) (differs)72 x 229 x 31280 x 80 x 42 (with preamplifier and microphone)
Operating temperature (°C) (differs)-10 to 50 (class 1); 0 to 40 (class 2)-10 to 50
Connectivity and software
Connectivity (differs)USB 2.0 Mini-B (mass storage)USB 2.0 Mini-B, 3.5 mm AC output, multipin I/O (AC and DC output)
Software (differs)Casella InsightAnalyzerPlus