Skip to content
soundlevelmeter.review

Compare instruments

Up to 4 instruments of the same type, every published specification side by side. Rows where the values differ are tinted. A blank cell means the manufacturer does not publish that value.

Comparing 2 noise dosimeters. Back to the category table.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationdBadge CEL-35xCaselladoseBadge5 Personal Noise Dosimeter (CR:120A)Cirrus Research
StatusDiscontinuedCurrent
Verified on
Standards and class
Standards (differs)IEC 61252:2002, BS EN 61252:1997, ANSI S1.25IEC 61252:1993 +AMD1:2000 (Ed 1.1, 2002-03), ANSI S1.25:1991 (R2017), IEC 61260-1:2014 class 2 and ANSI S1.11-2014 class 2 (octave bands)
Measurement
Channels (differs)16
Measurement range (differs)65.0 to 140.3 dB(A) RMS60 to 140 dB(A) RMS; linear operating range 65 to 140 dB(A)
Linearity range (differs)65.0 to 140.3 dB(A)65 to 140 dB(A)
Peak range (differs)95.0 to 143.3 dB (C or Z)80 to 143 dB(C)
Frequency range (differs)—63 Hz to 8 kHz (octave bands)
Frequency weightingsA, C, ZA, C, Z
Time weightings (differs)F, S, IF, S
Simultaneous weightings (differs)—Yes
Parameters (differs)LAeq, LCeq (Plus), Lavg, LCpeak, LZpeak, LAE, LASmax, TWA, LEP,d, Pa2hLeq/LAVG, LEP,d / LEX,8h / TWA, %Dose and estimated %Dose, Lpeak, sound exposure, ULT duration, SPL max and min, LCeq-LAeq (HML)
DosimetryYesYes
Exchange rates (differs)3 dB, 5 dB3 dB, 4 dB, 5 dB
Intrinsically safe marking (differs)ATEX I M1, II 1G, EEx ia IIC T2 (222 °C), EEx ia I; Ta -20 to +40 °C; microphone FM/CSA Class 1 Division 1 Groups A-D T2 (IS models)—
Analysis
Octave bands (differs)None1/1
Octave band filter class (differs)—class 2 (IEC 61260-1:2014)
Reverberation time (differs)No—
Building acoustics (differs)No—
Audio recording (differs)No—
Logging and data
Shortest logging interval (differs)1 min1 s
Memory (differs)—up to 80 h of time history (6 channels); up to 40 measurements; 24 h maximum single measurement
Hardware
Microphone (differs)1/2" CEL-252, 30 mV/Pa, type 2—
Detachable preamplifierNoNo
Display (differs)LCD with blue/red alarm LEDnone
Battery (differs)internal NiMH; full charge under 90 mininternal NiMH
Battery life (differs)28 h20 h
External power (differs)—charging dock (3 h from empty)
Weight (differs)68 g85 g
Dimensions (mm) (differs)72 x 47 x 5266 x 43 x 53 (excluding clips)
Operating temperature (°C) (differs)0 to 40-10 to 50
Connectivity and software
Connectivity (differs)infrared (193200B cable)Bluetooth, USB via charging dock
Remote control (differs)—doseBadge5 remote control wand; dBLink / MyCirrus app (iOS, Android)
Software (differs)Casella Insight, dB35NoiseTools, dBLink app
Latest firmware (differs)193026-01-15 (firmware file on support page)—

Change the selection

Choose up to 4 instruments of the same type. Instruments are grouped by brand; the type is shown after the model name.

Compare sound level meters | soundlevelmeter.review