Compare instruments
Up to 4 instruments of the same type, every published specification side by side. Rows where the values differ are tinted. A blank cell means the manufacturer does not publish that value.
Comparing 2 handheld sound level meters. Back to the category table.
| Specification | CESVA SC250CESVA | Svantek SVAN 979Svantek |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| IEC 61672-1 class | Class 1 | Class 1 |
| Standards (differs) | IEC 61672-1:2013 class 1, EN 61672-1:2013 class 1, ANSI S1.4:2014 part 1 class 1, ANSI S1.43-1997 (R2007) class 1, IEC 61260-1:2014 class 1, EN 61260-1:2014 class 1, ANSI S1.11-2004 (R2009) class 1, OIML R 58:1998, OIML R 88:1998, OIML R 130:2001, DIN 45657:2014 (Taktmaximalpegel), IEC 61010-1:2010 A1:2016 / EN 61010-1:2010 A1:2019 | IEC 61672-1:2013 class 1, IEC 61260-1:2014 class 1, ISO 1996-2 (tonality option), ISO 532B (loudness), ISO 20816 (vibration), IEC 60268-16 (STIPA option) |
| Pattern approvals (differs) | Spain (type examination 14/09/2021; additionals 24/02/2022, 18/04/2023, 04/06/2024), Portugal (30/03/2022), Czech Republic (22/06/2022), Switzerland (07/12/2022) | Pattern approval to IEC 61672 (bodies not named on page) |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | Single range, 16.5 dB(A) to 140.1 dB(C) peak | 12 dB(A) Leq to 140 dB(A) peak (total range) |
| Linearity range (differs) | — | 22 dB(A) Leq to 140 dB(A) peak |
| Peak range (differs) | — | up to 140 dB(A) peak |
| Frequency range (differs) | — | 3.15 Hz to 20 kHz |
| Frequency weightings (differs) | — | A, B, C, Z, G |
| Time weightings (differs) | — | F, S, I |
| Simultaneous weightings (differs) | — | Yes |
| Parameters (differs) | F1, F2 and F3 user-selected functions, NC and NR curve evaluation, pass / not pass against an adjustable threshold on F1 | Leq, SPL, Lmax, Lmin, Lpeak, SEL, Ln (L1 to L99), tonality, loudness, three parallel profiles |
| Analysis | ||
| Octave bands (differs) | 1/1 and 1/3 | 1/12 |
| Octave band filter class (differs) | 1/1 octave 8 Hz to 16 kHz; 1/3 octave 6.3 Hz to 20 kHz (optional module) | 1/1 and 1/3 octave class 1 (IEC 61260-1:2014) standard; 1/6 and 1/12 octave optional |
| FFT (differs) | — | up to 1600 lines, up to 25.6 kHz |
| Reverberation time (differs) | — | Yes |
| Building acoustics (differs) | — | Yes |
| Speech intelligibility (differs) | — | STIPA (option) |
| Audio recording (differs) | — | Yes |
| Logging and data | ||
| Shortest logging interval (differs) | — | 2 ms |
| Memory (differs) | Built in; recordings and final results saved as CSV, with a log of date, sensitivity and firmware changes | 32 GB microSD |
| Hardware | ||
| Microphone (differs) | — | 1/2" G.R.A.S. 40AE with SV 17 preamplifier; 200 V polarised microphones supported |
| Detachable preamplifier (differs) | — | Yes |
| Outdoor microphone kit (differs) | — | IP65 environmental case with internal battery, solar-ready charger and 4G modem (SV 279 PRO) |
| Display (differs) | 3.5 inch capacitive colour touch screen | Colour OLED with 9-key keypad (size not stated) |
| Battery (differs) | — | 4 x AA |
| Battery life (differs) | — | 8 h |
| Weight (differs) | — | 600 g |
| Dimensions (mm) (differs) | — | 310 x 79 x 39 |
| Operating temperature (°C) (differs) | — | -10 to 50 |
| Connectivity and software | ||
| Connectivity (differs) | USB-C, Bluetooth, WiFi (CESVACloud, firmware updates, module activation) | USB, RS-232, I/O, Bluetooth |
| Remote control (differs) | — | Mobile app for building acoustics; SvanNET in SV 279 PRO configuration |
| Software (differs) | CESVA Lab, Result Merging Tools (SE003), SC250 Link (Android) | SvanPC++, SvanNET, Building Acoustics app |