SpecificationOptimus+ Industrial Sound Level MeterCirrus ResearchSvantek SV 971ASvantek
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1:2013 class 1 or class 2, IEC 61672-1:2002 class 1 or class 2 group X, IEC 60651:2001 type 1 or type 2, IEC 60804:2000 type 1 or type 2, IEC 61252:1993, ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), ANSI S1.25:1991, IEC 61260:1996 and ANSI S1.11-2004 (octave band models), DIN 45657:2005-03IEC 61672-1:2013 class 1, IEC 61260-1:2014 class 1, ANSI/ASA S1.4, IEC 60268-16 (STIPA option)
Pattern approvals (differs)PTB (DIN EN 61672), optional, LNE (IEC 61672), optional, Leq and octave band modelsPTB (Germany), BEV (Austria), GUM Central Office of Measures (Poland)
Measurement
Channels11
Measurement range (differs)20 to 140 dB, single RMS range17 dB(A) Leq to 140 dB(A) peak (total range)
Linearity range (differs)—24 dB(A) Leq to 140 dB(A) peak
Peak range (differs)—up to 140 dB(A) peak
Frequency range (differs)31.5 Hz to 16 kHz (1:1 octave bands, C models)5 Hz to 20 kHz
Frequency weightings (differs)A, C, ZA, B, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightingsYesYes
Parameters (differs)LXY (X = A, C, Z; Y = F, S, I), LXYmax, LXYmin, LXeq, LCpeak, LZpeak, LApeak, LCeq-LAeq, LXE, LAIeq, LAVG, Dose and estimated dose, NR/NC (C models)Leq, SPL, Lmax, Lmin, Lpeak, SEL, Ln (L1 to L99), Dose, TWA, three parallel profiles
DosimetryYesYes
Exchange rates (differs)3 dB, 4 dB, 5 dB2 dB, 3 dB, 4 dB, 5 dB, 6 dB
Analysis
Octave bands (differs)1/11/1 and 1/3
Octave band filter class (differs)—class 1 (IEC 61260-1:2014), licensed option
Reverberation time (differs)—Yes
Building acoustics (differs)—Yes
Speech intelligibility (differs)—STIPA (option)
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)10 ms100 ms (2 ms in RT60 mode)
Memory (differs)8 GB standard; 32 GB factory optionmicroSD up to 32 GB
Hardware
Microphone (differs)class 1: MK:224 or MK:229 1/2" pre-polarised; class 2: MK:216 pre-polarised1/2" ACO 7152 (SV 7152) with SV 18A preamplifier
Detachable preamplifierYesYes
Display (differs)high-resolution colour display with ambient light sensor and illuminated keypadColour display with 8-key keypad (size not stated)
Battery (differs)4 x AA alkaline or lithium4 x AAA
Battery life (differs)12 h16 h
External power (differs)5 to 15 V DC via ZL:171 cable—
Weight (differs)300 g225 g
Dimensions (mm) (differs)283 x 65 x 30232.5 x 56 x 20
Operating temperature (°C)-10 to 50-10 to 50
Connectivity and software
Connectivity (differs)USB type B, Bluetooth Low Energy, AC/DC output (ZL:174 cable)USB-C, Bluetooth, WiFi/LAN via SvanLINK
Remote control (differs)MyCirrus mobile apps (iOS, Android) via BluetoothAssistant Pro app; Building Acoustics app; SvanLINK telemetry
Software (differs)NoiseTools, MyCirrus appAssistant Pro app, Building Acoustics Assistant app, SvanPC++