Compare instruments
Up to 4 instruments of the same type, every published specification side by side. Rows where the values differ are tinted. A blank cell means the manufacturer does not publish that value.
Comparing 2 noise monitoring stations. Back to the category table.
| Specification | Outdoor Environmental Noise Kit (CK:671B / CK:675B / CK:681B / CK:685B)Cirrus Research | Norsonic Nor1545Norsonic |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| IEC 61672-1 class | Class 1 | Class 1 |
| Standards (differs) | IEC 61672-1:2013 class 1 or class 2 (Optimus+ Environmental) | IEC 61672-1:2013 class 1 (Nor145), IEC 61260-1 class 1 (Nor145) |
| Pattern approvals (differs) | PTB (DIN EN 61672), optional, LNE (IEC 61672), optional | Nor145 approvals: PTB, LNE 37403-1, METAS, BEV, CIM, IPQ, GUM |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | 20 to 140 dB, single range (Optimus+ Environmental) | 17 to 137 dB(A) RMS (Nor145) |
| Peak range (differs) | — | 45 to 140 dB (C-weighted peak, Nor145) |
| Frequency range (differs) | — | 6.3 Hz to 20 kHz standard (Nor145); 0.4 Hz to 40 kHz with options |
| Frequency weightings | A, C, Z | A, C, Z |
| Time weightings | F, S, I | F, S, I |
| Simultaneous weightings | Yes | Yes |
| Parameters (differs) | LAeq, Ln, Lmax, Lmin | Leq, Lmax, Lmin, LE, Lpeak, Ln percentiles, event markers, noise direction (Nor1297) |
| Analysis | ||
| Octave bands | 1/1 and 1/3 | 1/1 and 1/3 |
| Octave band filter class (differs) | — | class 1 (IEC 61260) |
| FFT (differs) | — | Nor145 FFT option |
| Audio recording | Yes | Yes |
| Logging and data | ||
| Shortest logging interval (differs) | — | 5 ms (Nor145) |
| Memory (differs) | — | SD card in Nor145 |
| Hardware | ||
| Microphone (differs) | MK:172 outdoor microphone | Nor1216 heated outdoor microphone with Nor1227 cartridge, or Nor1217 with Nor1239 cartridge |
| Detachable preamplifier | Yes | Yes |
| Outdoor microphone kit (differs) | included: MK:172 outdoor microphone with protective cover | Nor1216 (permanent, heated, PTB approved) or Nor1217 (temporary) |
| Weather sensors (differs) | — | Yes |
| Display (differs) | Optimus+ meter display inside the case | 4.3" touchscreen of the Nor145 |
| Battery (differs) | 2 x lead acid or lithium-ion batteries (user choice) | Internal backup battery; Tracer Nor344 Li-polymer battery option (Nor1545/B) |
| Battery life (differs) | — | 7 h |
| External power (differs) | 12 to 18 V DC; weatherproof mains power supply; solar | 88 to 264 V AC; 9 to 28 V DC; solar panel; typical consumption 3.5 W |
| Autonomy on internal power (differs) | 12 days | 3 days |
| Weight (differs) | 14100 g | 3300 g |
| Dimensions (mm) (differs) | 465 x 180 x 355 | 200 x 132 x 400 |
| IP rating (differs) | — | IP66 (IP67 with extra sealant in the cable gland) |
| Operating temperature (°C) (differs) | — | -20 to 50 (battery charging 0 to 40) |
| Connectivity and software | ||
| Connectivity (differs) | modem (Remote Access version), GPS (Remote Access version), USB (meter download) | LAN, WiFi, 3G/UMTS, 4G/LTE, GPS, digital I/O (Nor1545/B) |
| Remote control (differs) | MyCirrus cloud platform and MyCirrus Notifications app (Remote Access version) | NorCloud |
| Software (differs) | NoiseTools, MyCirrus, MyCirrus Notifications app | NorCloud, NorReview |
| Latest firmware (differs) | — | Nor145 6.0.3025 (25 June 2026) |