Skip to content
soundlevelmeter.review

Compare instruments

Up to 4 instruments of the same type, every published specification side by side. Rows where the values differ are tinted. A blank cell means the manufacturer does not publish that value.

Comparing 2 handheld sound level meters. Back to the category table.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationSoundTrack LxTLarson DavisNovaPulsar Instruments
StatusDiscontinuedCurrent
Verified on
Manufacturer list priceGBP 1,100
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1:2013 class 1 (LxT1) or class 2 (LxT2), ANSI S1.4-2014 class 1 or class 2, ANSI S1.43-1997 (R2002), IEC 61260:2001 class 1 / ANSI S1.11-2004 class 1 (octave filters, option), IEC 60651:2001, IEC 60804:2000, ISO 9612:2009 measurement strategies supportedIEC 61672-1:2013 class 1 or class 2, group X, IEC 61672-2:2013, IEC 60651:2001 type 1 I or type 2 I, IEC 60804:2000 type 1 or type 2, IEC 61252:1993, ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), ANSI S1.25:1991, IEC 61260 and ANSI S1.11-2004 (1/1 octave filters)
Recommended calibration interval (differs)—12 months
Measurement
Channels11
Measurement range (differs)17 to 118 dB(A), 19 to 118 dB(C), 24 to 118 dB(Z) typical dynamic range (single range; LxT1 with 377B02)20 to 140 dB RMS, single range
Peak range (differs)—up to 143 dB
Frequency range (differs)1/1 octave 8 Hz to 16 kHz; 1/3 octave 6.3 Hz to 20 kHz (filter options)—
Frequency weightingsA, C, ZA, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightings (differs)—Yes
Parameters (differs)SPL, Leq, Lmax, Lmin, SEL, Lpeak, Lpeak(max), Ln (6 values L0.01 to L99.99), Lavg, TWA, Dose, ProjDose, Lep,d, E, E8, E40, SEALxy, Lxy max/min, Lxeq, LCpeak, LZpeak, LApeak, LCeq-LAeq, LxE, LAIeq, Ln (14 values), TWA, Dose %, estimated Dose %
DosimetryYesYes
Exchange rates (differs)—3 dB, 4 dB, 5 dB
Analysis
Octave bands (differs)1/1 and 1/31/1
Octave band filter class (differs)options LXT-OB1 (1/1) and LXT-OB3 (1/3 and 1/1)IEC 61260 and ANSI S1.11-2004, 31.5 Hz to 16 kHz (Models 45/46)
Reverberation time (differs)—No
Building acoustics (differs)—No
Audio recording (differs)—Yes
Logging and data
Shortest logging interval (differs)100 ms (option LXT-HSLOG); 1 s with LXT-LOG10 ms (time history); periodic 1 min to 1 h and Lden
Memory (differs)2 GB4 GB removable memory card
Hardware
Microphone (differs)1/2" 377B02 free-field 50 mV/Pa (LxT1) or 375A04 (LxT2); optional 377C20 random-incidence; preamplifier PRMLXT1 or PRMLXT2C; drives up to 61 m extension cable1/2" prepolarised PM1 (class 1) or PM2 (class 2); PA40 removable preamplifier
Detachable preamplifierYesYes
Outdoor microphone kit (differs)—WK3-N outdoor kit with PM172 outdoor microphone
Display (differs)160 x 240 pixel backlit LCDOLED with ambient light sensor (product description says TFT)
Battery (differs)4 x AA (alkaline, NiMH or 1.5 V lithium); PSA029 mains supply; BAT015 external D-cell holder6 x AA; external 5 to 15 V DC via I/O socket
Battery life (differs)16 h30 h
External power (differs)USB/power port; optional BAT015 external D-cell pack (over 13 days)—
Weight (differs)513 g440 g
Dimensions (differs)290 x 71 x 41 overall (body 224 mm long)280 x 80 x 42 (with preamplifier and microphone)
Operating temperature (°C) (differs)-10 to 50 (sensitivity within +/-0.5 dB); storage -30 to 60-10 to 50
Connectivity and software
Connectivity (differs)USB 2.0, auxiliary USB for storage, AC/DC output and headset jackUSB 2.0 Mini-B, 3.5 mm AC output, multipin I/O (AC and DC output)
Software (differs)G4 LD Utility (SWW-SLM-UTILG4), Blaze (SWW-BLAZE-LXT), DNAAnalyzerPlus
Latest firmware (differs)2.404 (reference manual revision R)—

Change the selection

Choose up to 4 instruments of the same type. Instruments are grouped by brand; the type is shown after the model name.

Compare sound level meters | soundlevelmeter.review