TSI Quest · OmniWear · Noise dosimeter
TSI OmniWear Noise (OW-N-DVE)
CurrentLightweight (36 g) personal noise dosimeter worn in the hearing zone, with a MEMS microphone, IP65 rating and a 16-hour run time. It is set up, started and stopped over Bluetooth from the OmniWear Noise mobile app, which can manage up to 20 units and generates PDF reports. Announced in July 2025; sold in the UK and Europe at the time of access.
Launched 2025. Specifications verified on .
- Type
- Noise dosimeter
- Channels
- 1
- Connectivity
- Bluetooth
- Weight
- 36 g
- Battery life
- 16 h
Specifications
As published by TSI Quest. Fields the manufacturer does not publish are omitted rather than estimated.
| Specification | Value |
|---|---|
| Standards | IEC 61252:1997 + A2:2017 (BS EN), ANSI S1.25:1991 (R2024) |
| Specification | Value |
|---|---|
| Channels | 1 |
| Measurement range | 70 to 140.3 dB(A) RMS (linear operating range) |
| Linearity range | 70 to 140.3 dB(A) |
| Peak range | 90.0 to 143.3 dB (C or Z weighted) |
| Frequency weightings | A, C, Z |
| Time weightings | F, S, I |
| Parameters | LXY, LXYmax, LXeq, LXpeak, Lavg, LXIeq, LTM3, LTM5, LAE, LAep,d, LEX,8h, TWA, Dose % (incl. projected), Pa2h, Pa2s, Motion %, time above threshold |
| Dosimetry | Yes |
| Exchange rates | 3 dB, 5 dB |
| Specification | Value |
|---|---|
| Shortest logging interval | 1 s |
| Memory | 64 runs maximum |
| Specification | Value |
|---|---|
| Microphone | MEMS microphone |
| Display | none (multifunction LED status indicator and one action button) |
| Battery | Rechargeable Li-ion 350 mAh; wireless drop-in charger (4 h to 85 %, 6 h to 100 %) |
| Battery life | 16 h |
| Weight | 36 g |
| Dimensions (mm) | 56 x 32 x 40 |
| IP rating | IP65 |
| Operating temperature (°C) | 0 to 40 (< +/-0.5 dB error); -10 to 50 (< +/-0.8 dB error) |
| Specification | Value |
|---|---|
| Connectivity | Bluetooth |
| Remote control | OmniWear Noise app (iOS, Android) |
| Software | OmniWear Noise app |
Where this data comes from
| Kind | Document | Accessed |
|---|---|---|
| Product page | OmniWear Noise Dosimeter | |
| Press release | Introducing TSI OmniWear Noise (10 July 2025) | |
| Datasheet | OmniWear Noise Spezifikationsblatt P/N 5003313 Rev B (German-language edition of spec sheet 5003270) | |
| Manual | OmniWear Noise User Manual P/N 6018423 (linked from product page; not opened) |
Verified on . Only the manufacturer’s own published material is used; distributor pages are not sources.
Spec out of date? Tell us (reference tsi-quest-omniwear-noise).
Verified owner reviews
Reviews from people who own and use this instrument, each checked against a serial number by a person.
Opens in November 2026. Own this instrument? Register your interest.
Known issues and firmware notes
Hardware and firmware problems reported by owners, with the firmware version concerned and any manufacturer response.
Opens in November 2026. Own this instrument? Register your interest.
Feature requests
Functions owners would like to see in a firmware update or a successor model.
Opens in November 2026. Own this instrument? Register your interest.
Read next
- How to choose a noise dosimeter · IEC 61252, exchange rates, criterion levels, badge vs cable, intrinsic safety, logging and audio.
- Sound level meter calibration and verification · Field calibration vs laboratory calibration, IEC 61672-3, ISO 17025, intervals, reading a certificate.
Related instruments
More from TSI Quest
- Quest Edge 4+ (EG4P) · TSI Quest
- Quest Edge 5 (EG5) · TSI QuestDiscontinued
- Quest Edge 7 (EG7) · TSI Quest · Class 2
- Quest Edge 8 (EG8) · TSI Quest · Class 2
Other noise dosimeters
- dBadge CEL-35x · CasellaDiscontinued
- The doseBadge (CR:130A) · Cirrus ResearchAnnounced
- Brüel & Kjær 4448 · HBK (Brüel & Kjær)Discontinued
- Spartan 730IS · Larson Davis