Compare instruments
Up to 4 instruments of the same type, every published specification side by side. Rows where the values differ are tinted. A blank cell means the manufacturer does not publish that value.
Comparing 2 noise monitoring stations. Back to the category table.
| Specification | CESVA TA120CESVA | Rion NA-39ARion |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| IEC 61672-1 class | Class 1 | Class 1 |
| Standards (differs) | IEC 61672-1 class 1 (measurement), IEC 60942 (calibrator used for field checks), IEC 60529:2013 (IP65) | IEC 61672-1:2013 class 1, IEC 61260:2014 class 1, JIS C 1509-1:2017 class 1, JIS C 1516:2020 |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | Single range, 35 to 120 dB(A) | A 28 to 138 dB; C 36 to 138 dB; Z 42 to 138 dB |
| Frequency range (differs) | — | 10 Hz to 20 kHz |
| Frequency weightings (differs) | A, C | A, C, Z |
| Time weightings (differs) | F, S | F, S, I |
| Parameters (differs) | LAeq, one selectable additional function: LCeq, LAFmax or LASmax | Lp, Leq, Lmax, Lmin, Lpeak, event data, SSR data |
| Analysis | ||
| Octave bands (differs) | None | 1/3 |
| Octave band filter class (differs) | — | class 1 (IEC 61260:2014), real-time, standard |
| Reverberation time (differs) | — | No |
| Building acoustics (differs) | — | No |
| Audio recording (differs) | — | Yes |
| Logging and data | ||
| Shortest logging interval (differs) | Integration time configurable from 1 s to 60 min; per-second values available | 100 ms |
| Memory (differs) | — | SDHC card (8 GB supplied) plus 4 GB internal backup |
| Hardware | ||
| Microphone (differs) | — | Outdoor Microphone MS-11A, 1/2" electret, -28 dB, built-in check source, optional heater |
| Outdoor microphone kit (differs) | PV120 windscreen; TK120 outdoor kit | MS-11A outdoor microphone with WS-13 all-weather windscreen (IPX3) |
| Weather sensors (differs) | — | Yes |
| Display (differs) | — | Monochrome backlit LCD, 64 x 128 |
| Battery (differs) | — | 12 V sealed lead-acid backup (optional) |
| External power (differs) | Mains, Power over Ethernet, or 12 V DC (solar panel or external battery); optional BA120 battery for urban lighting networks | 100 to 240 V AC; 9 to 15 V DC |
| Weight (differs) | — | 1500 g |
| Dimensions (mm) (differs) | — | 200 x 140 x 79 (main unit, excluding microphone and cables) |
| IP rating (differs) | IP65 | — |
| Operating temperature (°C) | -10 to 50 | -10 to 50 |
| Connectivity and software | ||
| Connectivity (differs) | Ethernet (RJ45), WiFi (optional), GPRS / 2G modem (optional), 4-20 mA current loop (optional, CL120), HTTP/HTTPS, UL2.0 or JSON | LAN (10BASE-T/100BASE-TX), modem, GPS, weather meter connector, AC output |
| Remote control (differs) | Reports over HTTP/HTTPS to NoisePlatform; configurable remotely | Aircraft Noise Data Processing Software AS-51; NTP or GPS clock |
| Software (differs) | NoisePlatform | AS-51 Aircraft Noise Data Processing Software, NX-39WR Real Sound Recording Software |