Skip to content
soundlevelmeter.review

CESVA · Noise monitoring station

CESVA TA120

Current

Permanently installed outdoor noise sensor measuring to class 1, reporting LAeq and one selectable function over Ethernet, WiFi or a GPRS modem to the CESVA NoisePlatform, powered from mains, PoE or 12 V.

Specifications verified on .

Type
Noise monitoring station
Class
Class 1
Channels
1
Octave bands
None
Connectivity
Ethernet (RJ45), WiFi (optional), GPRS / 2G modem (optional), 4-20 mA current loop (optional, CL120), HTTP/HTTPS, UL2.0 or JSON
Compare with other instrumentsAll noise monitoring stations

Specifications

As published by CESVA. Fields the manufacturer does not publish are omitted rather than estimated.

Standards and class — CESVA TA120
SpecificationValue
IEC 61672-1 classClass 1
StandardsIEC 61672-1 class 1 (measurement), IEC 60942 (calibrator used for field checks), IEC 60529:2013 (IP65)
Measurement — CESVA TA120
SpecificationValue
Channels1
Measurement rangeSingle range, 35 to 120 dB(A)
Frequency weightingsA, C
Time weightingsF, S
ParametersLAeq, one selectable additional function: LCeq, LAFmax or LASmax
Analysis — CESVA TA120
SpecificationValue
Octave bandsNone
Logging and data — CESVA TA120
SpecificationValue
Shortest logging intervalIntegration time configurable from 1 s to 60 min; per-second values available
Hardware — CESVA TA120
SpecificationValue
Outdoor microphone kitPV120 windscreen; TK120 outdoor kit
External powerMains, Power over Ethernet, or 12 V DC (solar panel or external battery); optional BA120 battery for urban lighting networks
IP ratingIP65
Operating temperature (°C)-10 to 50
Connectivity and software — CESVA TA120
SpecificationValue
ConnectivityEthernet (RJ45), WiFi (optional), GPRS / 2G modem (optional), 4-20 mA current loop (optional, CL120), HTTP/HTTPS, UL2.0 or JSON
Remote controlReports over HTTP/HTTPS to NoisePlatform; configurable remotely
SoftwareNoisePlatform

Questions about the CESVA TA120

What accuracy class is the CESVA TA120?
The manufacturer states class 1 to IEC 61672-1.
Which standards does the CESVA TA120 meet?
The manufacturer lists IEC 61672-1 class 1 (measurement), IEC 60942 (calibrator used for field checks) and IEC 60529:2013 (IP65).
What is the measurement range of the CESVA TA120?
The manufacturer publishes a measurement range of Single range, 35 to 120 dB(A) dB.
Does the CESVA TA120 measure octave bands?
No, according to the manufacturer's published specification.
Is the CESVA TA120 still sold?
Yes, it is a current product on the manufacturer's site.

Answers are taken from the specification above and its sources.

Where this data comes from

Manufacturer documents used for this record
KindDocumentAccessed
Product pageTA120 - Noise measuring sensor for Smart Solutions
OtherNoisePlatform

Verified on . Only the manufacturer’s own published material is used; distributor pages are not sources.

Spec out of date, or something here wrong? Report it — no account needed. You can also e-mail us.

From owners

Anyone with an account can write here. A reviewer who also confirms the instrument’s serial number is shown as a verified owner, and only those reviews count towards the score. Everything is read by a moderator before publication, except feature requests, which are checked afterwards.

Owner reviews (0)

Write a review

No verified-owner reviews yet.

Known issues and firmware notes (0)

Report an issue

No issues reported.

Feature requests (0)

Vote on requestsPost a request

No requests yet.

Used CESVA TA120 for sale (0)

Sell yours

None at the moment. All used instruments.

Compare with

Specification by specification, from each manufacturer’s own published figures.

More from CESVA

Other class 1 noise monitoring stations