Up to 4 instruments of the same type, every published specification side by side. Rows where the values differ are tinted. A blank cell means the manufacturer does not publish that value.

Comparing 2 noise monitoring stations. Back to the category table.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationCESVA TA120CESVAWatchSoft dB
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1 class 1 (measurement), IEC 60942 (calibrator used for field checks), IEC 60529:2013 (IP65)IEC 61672-1 class 1, ANSI S1.4 class 1, IEC 61260-1 / ANSI S1.11-1:2014 class 1 (1/3 octave, SAS), ISEE and AS 2187.2 (blast overpressure), DIN 4150-3, ISEE, AS 2187.2, BS 7385-2 (vibration)
Measurement
Channels (differs)13
Measurement range (differs)Single range, 35 to 120 dB(A)117 dB dynamic range (Smart Acoustic Sensor); under-range 30 to 42 dBA (low range) or 42 to 54 dBA (high range) depending on microphone
Peak range (differs)—125 to 137 dBZpk (low range), 137 to 149 dBZpk (high range), depending on microphone
Frequency range (differs)—0.5 Hz to 21 kHz
Frequency weightings (differs)A, CA, C, Z, G
Time weightingsF, SF, S
Parameters (differs)LAeq, one selectable additional function: LCeq, LAFmax or LASmaxLeq, Lmax, Lmin, Lpeak, SEL, LN (1 to 99 %), LAFTm5
Analysis
Octave bands (differs)None1/3
Octave band filter class (differs)—class 1, 6.3 Hz to 20 kHz (Smart Acoustic Sensor)
FFT (differs)—512 lines (Smart Acoustic Sensor)
Audio recording (differs)—Yes
Logging and data
Shortest logging interval (differs)Integration time configurable from 1 s to 60 min; per-second values available1 s
Hardware
Microphone (differs)—Smart Acoustic Sensor (SAS) with 50 mV/Pa or 12.6 mV/Pa microphone; diameter not stated
Outdoor microphone kit (differs)PV120 windscreen; TK120 outdoor kitSmart Acoustic Sensor with windscreen, bird spike and full microphone environmental protection (IP54 in vertical position)
Weather sensors (differs)—Yes
Battery (differs)—Internal battery; external battery, AC mains, solar or hybrid via power management module
External power (differs)Mains, Power over Ethernet, or 12 V DC (solar panel or external battery); optional BA120 battery for urban lighting networksinternal battery, external battery, AC mains, solar panel, hybrid
Autonomy on internal power (differs)—29 days
IP rating (differs)IP65—
Operating temperature (°C) (differs)-10 to 50-40 to 40
Connectivity and software
Connectivity (differs)Ethernet (RJ45), WiFi (optional), GPRS / 2G modem (optional), 4-20 mA current loop (optional, CL120), HTTP/HTTPS, UL2.0 or JSONLTE/4G, GPS, USB-C, RS-485 (Smart Sensor bus)
Remote control (differs)Reports over HTTP/HTTPS to NoisePlatform; configurable remotelySoft dB Web Platform (dashboard, alerts, API, over-the-air firmware)
Software (differs)NoisePlatformSoft dB Web Platform

Change the selection

Choose up to 4 instruments of the same type. Instruments are grouped by brand; the type is shown after the model name.