Skip to content
soundlevelmeter.review

CESVA · Noise monitoring station

CESVA TA150

Current

Class 1 outdoor noise monitoring terminal with a built-in web server, optional third-octave analysis, optional triggered audio recording and a choice of Ethernet, WiFi or 4G, powered from mains, PoE, 12 V or street lighting.

Specifications verified on .

Type
Noise monitoring station
Class
Class 1
Channels
1
Octave bands
1/3
Connectivity
Ethernet, WiFi, built-in web server, 4G modem (optional, MR154), GPS (optional, with 4G), 4-20 mA (optional, CL150), RS-232 (optional, RS152), RS-485 (optional, RS154)
Compare with other instrumentsAll noise monitoring stations

Specifications

As published by CESVA. Fields the manufacturer does not publish are omitted rather than estimated.

Standards and class — CESVA TA150
SpecificationValue
IEC 61672-1 classClass 1
StandardsIEC 61672-1 class 1, IEC 60942 (calibrator used for field checks), IEC 60529:2013 (IP65)
Measurement — CESVA TA150
SpecificationValue
Channels1
Frequency weightingsA, C, Z
Time weightingsF, S, I
Parametersequivalent levels, maximum levels, peak levels, percentile levels
Analysis — CESVA TA150
SpecificationValue
Octave bands1/3
Octave band filter class1/3 octave 6.3 Hz to 20 kHz (optional FR150 module)
Audio recordingYes
Hardware — CESVA TA150
SpecificationValue
Outdoor microphone kitTK120 outdoor kit including the PV120 windscreen
External powerMains, Power over Ethernet, 12 V DC or street lighting; specification list states 5 to 12 V DC; optional internal batteries BA150 and BA152
IP ratingIP65
Operating temperature (°C)-10 to 50
Connectivity and software — CESVA TA150
SpecificationValue
ConnectivityEthernet, WiFi, built-in web server, 4G modem (optional, MR154), GPS (optional, with 4G), 4-20 mA (optional, CL150), RS-232 (optional, RS152), RS-485 (optional, RS154)
Remote controlBuilt-in web server; reports to NoisePlatform
SoftwareNoisePlatform

Questions about the CESVA TA150

What accuracy class is the CESVA TA150?
The manufacturer states class 1 to IEC 61672-1.
Which standards does the CESVA TA150 meet?
The manufacturer lists IEC 61672-1 class 1, IEC 60942 (calibrator used for field checks) and IEC 60529:2013 (IP65).
Does the CESVA TA150 measure octave bands?
Yes: 1/3 octave bands, filter class 1/3 octave 6.3 Hz to 20 kHz (optional FR150 module), according to the manufacturer.
Is the CESVA TA150 still sold?
Yes, it is a current product on the manufacturer's site.

Answers are taken from the specification above and its sources.

Where this data comes from

Manufacturer documents used for this record
KindDocumentAccessed
Product pageTA150 - Spectrum analyser sensor for noise measurement
OtherNoisePlatform

Verified on . Only the manufacturer’s own published material is used; distributor pages are not sources.

Spec out of date, or something here wrong? Report it — no account needed. You can also e-mail us.

From owners

Anyone with an account can write here. A reviewer who also confirms the instrument’s serial number is shown as a verified owner, and only those reviews count towards the score. Everything is read by a moderator before publication, except feature requests, which are checked afterwards.

Owner reviews (0)

Write a review

No verified-owner reviews yet.

Known issues and firmware notes (0)

Report an issue

No issues reported.

Feature requests (0)

Vote on requestsPost a request

No requests yet.

Used CESVA TA150 for sale (0)

Sell yours

None at the moment. All used instruments.

Compare with

Specification by specification, from each manufacturer’s own published figures.

More from CESVA

Other class 1 noise monitoring stations