Skip to content
soundlevelmeter.review

Aihua AWA5662 vs Svantek SV 971A

Every specification Hangzhou Aihua Instruments and Svantek publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationAihua AWA5662Hangzhou Aihua InstrumentsSvantek SV 971ASvantek
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1:2013 class 1, IEC 61260-1:2014 class 1, IEC 61252:2025 (AWA5662-1)IEC 61672-1:2013 class 1, IEC 61260-1:2014 class 1, ANSI/ASA S1.4, IEC 60268-16 (STIPA option)
Pattern approvals (differs)—PTB (Germany), BEV (Austria), GUM Central Office of Measures (Poland)
Measurement
Channels11
Measurement range (differs)25 to 140 dB(A), 115 dB linear range without range switching; 16 to 131 dB(A) with low-level microphone; 48 to 163 dB(A) or 62 to 174 dB(A) with high-level microphones17 dB(A) Leq to 140 dB(A) peak (total range)
Linearity range (differs)—24 dB(A) Leq to 140 dB(A) peak
Peak range (differs)—up to 140 dB(A) peak
Frequency range (differs)10 Hz to 20 kHz5 Hz to 20 kHz
Frequency weightings (differs)A, C, ZA, B, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightings (differs)—Yes
Parameters (differs)Lp, Leq,T, Lmax, Lmin, LE, Lpeak, E, TWA, Lex,8h, LCpeak, LZpeak, LAVG, DOSE, NLApeak, Ln, SDLeq, SPL, Lmax, Lmin, Lpeak, SEL, Ln (L1 to L99), Dose, TWA, three parallel profiles
DosimetryYesYes
Exchange rates (differs)—2 dB, 3 dB, 4 dB, 5 dB, 6 dB
Analysis
Octave bands1/1 and 1/31/1 and 1/3
Octave band filter class (differs)class 1class 1 (IEC 61260-1:2014), licensed option
Reverberation time (differs)—Yes
Building acoustics (differs)—Yes
Speech intelligibility (differs)—STIPA (option)
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)—100 ms (2 ms in RT60 mode)
Memory (differs)4 GB internal (not on AWA5662-0), TF card up to 64 GB optionalmicroSD up to 32 GB
Hardware
Microphone (differs)AWA14425 standard; AWA14411 low-level; AWA14521 and AWA14434 high-level1/2" ACO 7152 (SV 7152) with SV 18A preamplifier
Detachable preamplifier (differs)—Yes
Display (differs)2.4 inch colour, 240 x 320Colour display with 8-key keypad (size not stated)
Battery (differs)4 x LR6 (AA) alkaline4 x AAA
Battery life (differs)—16 h
External power (differs)5 V external supply—
Weight (differs)340 g225 g
Dimensions (mm) (differs)250 x 76 x 33232.5 x 56 x 20
Operating temperature (°C) (differs)-20 to 60-10 to 50
Connectivity and software
Connectivity (differs)USB, AC output, DC output, I/OUSB-C, Bluetooth, WiFi/LAN via SvanLINK
Remote control (differs)—Assistant Pro app; Building Acoustics app; SvanLINK telemetry
Software (differs)—Assistant Pro app, Building Acoustics Assistant app, SvanPC++

The instruments on their own