Every specification Bedrock and Cirrus Research publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationBedrock AM100BedrockOptimus+ Environmental Sound Level MeterCirrus Research
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672 group X class 1, ANSI S1.4 type 1, IEC 61260 class 1, IEC 60268-16 rev. 4, ISO 3382-2, ANSI S12.2, ISO 1996IEC 61672-1:2013 class 1 or class 2, IEC 61260 and ANSI S1.11-2004 (1:1 and 1:3 octave filters), IEC 60651, IEC 60804, ANSI S1.4, ANSI S1.43, DIN 45657
Pattern approvals (differs)—PTB (class 1), LNE (class 1)
Recommended calibration interval (differs)—12 months
Measurement
Channels (differs)21
Measurement range (differs)24 to 118 dB (low range); 42 to 124 dB (high range), Z-weighted, with the supplied microphone20 to 140 dB, single range
Linearity range (differs)24 to 118 dB (low range); 42 to 124 dB (high range)—
Peak range (differs)up to 128 dB (high range, 20 Hz to 20 kHz)—
Frequency range (differs)10 Hz to 20 kHz per channel6.3 Hz to 20 kHz (1:3 octave bands measured; 12.5 Hz to 20 kHz displayed)
Frequency weightingsA, C, ZA, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightings (differs)—Yes
Parameters (differs)Leq, SEL, Lpeak, percentile levels, RT60, STI, NR/NC/PNC/NCB/RC curves, THD+NLXeq, LXYmax, LXYmin, LCpeak, LZpeak, LXE, Ln statistics, Lden, Leq LF (20 to 200 Hz), tonal noise detection (C models)
Analysis
Octave bands1/1 and 1/31/1 and 1/3
Octave band filter class (differs)class 1 (IEC 61260); 1/6 and 1/12 octave also available—
FFT (differs)800, 1600 or 3200 lines, 100 Hz to 20 kHz—
Reverberation time (differs)Yes—
Building acoustics (differs)Yes—
Speech intelligibility (differs)STIPA and Full STI—
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)—10 ms
Memory (differs)30 GB internal for user data plus 2 GB system partition8 GB standard; 32 GB factory option
Hardware
Microphone (differs)BAMT1-MP201 1/2" omnidirectional free-field, class 1, XLR 48 V phantom, 50 mV/Paclass 1: MK:224 1/2" pre-polarised; class 2: MK:216 pre-polarised
Detachable preamplifierYesYes
Outdoor microphone kit (differs)BOMK00 outdoor monitoring kit; BOC01 outdoor microphone housingOutdoor Environmental Noise Kit (CK:67x/68x) with MK:172 outdoor microphone
Display (differs)capacitive touch TFT, 800 x 480high-resolution OLED with ambient light sensor and illuminated keypad
Battery (differs)NiMH pack, 4.8 V, 2500 mAh4 x AA alkaline or lithium
Battery life (differs)4 h12 h
External power (differs)USB charging, max. 1.8 A; external LiFePO4 battery via BOMK00 kit5 to 15 V DC via ZL:171 cable
Weight (differs)600 g300 g
Dimensions (mm) (differs)210 x 85 x 55 (excluding microphone)283 x 65 x 30
Operating temperature (°C) (differs)5 to 35-10 to 50
Connectivity and software
Connectivity (differs)WiFi, LAN, Bluetooth, USB 2.0USB type B, Bluetooth Low Energy, AC/DC output, GPS (GPS model)
Remote control (differs)Bluetooth remote control; remote API for data streamingMyCirrus mobile apps via Bluetooth; remote access via Outdoor Kit modem
Software (differs)Bedrock Elite Analyzer, Bedrock StudioNoiseTools, MyCirrus app

The instruments on their own