Skip to content
soundlevelmeter.review

dBadge2 vs Quest Edge 4+ (EG4P)

Every specification Casella and TSI Quest publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationdBadge2CasellaQuest Edge 4+ (EG4P)TSI Quest
StatusCurrentCurrent
Verified on
Standards and class
Standards (differs)IEC 61252 Ed. 1.1b:2002, ANSI S1.25-1991 (R2007), IEC 61260:2014 class 2 (Pro filters), ANSI/ASA S1.11-2014 class 2 (Pro filters)ANSI S1.25 (personal noise dosimeters), IEC 61252 (personal sound exposure meters)
Measurement
Channels11
Measurement range (differs)54.0 to 140.3 dB(A) RMS, dynamic range 96 dB70 to 140 dB
Linearity range (differs)54.0 to 140.3 dB(A)—
Peak range (differs)90.0 to 143.3 dB (C or Z)110 to 143 dB
Frequency weightingsA, C, ZA, C, Z
Time weightings (differs)F, S, IF, S
Parameters (differs)Lavg, TWA(8h), projected TWA, Dose, projected Dose, LAeq, LCeq, LAIeq, LEP,d / LEX,8h, LApk, LCpk, LZpk, LAFmax, LASmax, LAImax, Pa2h, LC-LA (HML), Lpk counts > 135/137/140 dB, LAE, Motion IndexLavg, Leq, SPL, Lmax, Lmin, SEL (LEP), Dose, TWA, Lpeak, exposure, time above threshold, upper limit time
DosimetryYesYes
Exchange rates (differs)3 dB, 5 dB3 dB, 4 dB, 5 dB
Intrinsically safe marking (differs)ATEX/IECEx: I M1; II 1GD; Ex ia I Ma; Ex ia IIC T4 (135 °C) Ga; Ex ia IIIC T135 °C Da; Ta = -20 °C to +45 °C (IS models)—
Analysis
Octave bands (differs)1/1None
Octave band filter class (differs)class 2 (IEC 61260:2014), 9 bands 31.5 Hz to 8 kHz (Pro)—
Reverberation time (differs)No—
Building acoustics (differs)No—
Audio recording (differs)Yes—
Logging and data
Shortest logging interval (differs)1 s1 min
Memory (differs)internal microSD, 300 h of run data including 1 s profile; up to 90 min event audio180 hours
Hardware
Microphone (differs)1/2" CEL-252, 31.6 mV/Pa, type 21/4" prepolarised condenser (electret), threaded, field-replaceable
Detachable preamplifier (differs)No—
Display (differs)96 x 64 full-colour OLED128 x 64 colour OLED with configurable auto shut-off
Battery (differs)internal NiMH 800 mAh; about 10 h charge (manual also states about 6 h)Lithium polymer flat cell; charged in EdgeDock (2 to 4 h)
Battery life (differs)55 h20 h
Weight (differs)117 g85 g
Dimensions (mm) (differs)85 x 54 x 5588 x 53 x 19
IP rating (differs)IP65 (with permeable air vent)IP65
Operating temperature (°C) (differs)0 to 40 (for IEC 61252 compliance); -10 to 50 within 0.8 dB-10 to 50; storage -25 to 60
Connectivity and software
Connectivity (differs)Bluetooth 4.0 Low EnergyBluetooth (optional), USB via docking station
Remote control (differs)Airwave app (Android)Edge dB mobile app (iOS, Android)
Software (differs)Casella Insight, AirwaveDetection Management Software (DMS), Edge dB app

The instruments on their own

Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.