Skip to content
soundlevelmeter.review

CESVA TA120 vs NoiseWatch

Every specification CESVA and Soft dB publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationCESVA TA120CESVANoiseWatchSoft dB
StatusCurrentDiscontinued
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1 class 1 (measurement), IEC 60942 (calibrator used for field checks), IEC 60529:2013 (IP65)IEC 61672-1 / ANSI S1.4-1:2013 class 1, ANSI S1.43:2007 type 1
Measurement
Channels11
Measurement range (differs)Single range, 35 to 120 dB(A)Under-range 25 dBA (low range) or 31 dBA (high range); peak maximum 100 dBZpk (low) or 110 dBZpk (high)
Peak range (differs)—100 dBZpk (low range), 110 dBZpk (high range) maximum
Frequency weightings (differs)A, CA, C, Z
Time weightingsF, SF, S
Parameters (differs)LAeq, one selectable additional function: LCeq, LAFmax or LASmaxLeq, Lmax, Lmin, Lpeak, SEL, LN (1, 2, 5, 8, 10, 50, 90, 95, 99 %)
Analysis
Octave bands (differs)None1/1 and 1/3
Octave band filter class (differs)—1/1 octave 31.5 Hz to 8 kHz; 1/3 octave 20 Hz to 16 kHz; class not stated
FFT (differs)—400 lines, 6 bandwidths from 17.2 kHz to 539 Hz
Audio recording (differs)—Yes
Logging and data
Shortest logging interval (differs)Integration time configurable from 1 s to 60 min; per-second values available1 s
Memory (differs)—Looping buffer: 81,600 records without FFT, 16,320 with FFT; 11 min 50 s of audio
Hardware
Microphone (differs)—Electret condenser, nominal sensitivity 60 mV/Pa; diameter not stated
Outdoor microphone kit (differs)PV120 windscreen; TK120 outdoor kitAll-weather windscreen
Battery (differs)—Internal 168 Wh (12 V, 14 Ah) battery
Battery life (differs)—132 h
External power (differs)Mains, Power over Ethernet, or 12 V DC (solar panel or external battery); optional BA120 battery for urban lighting networksmains supply, optional 30 W solar panel
Autonomy on internal power (differs)—5.5 days
Weight (differs)—8900 g
Dimensions (mm) (differs)—324 x 273 x 145
IP rating (differs)IP65IP66 (NEMA Type 4)
Operating temperature (°C) (differs)-10 to 50-20 to 40
Connectivity and software
Connectivity (differs)Ethernet (RJ45), WiFi (optional), GPRS / 2G modem (optional), 4-20 mA current loop (optional, CL120), HTTP/HTTPS, UL2.0 or JSONLTE/4G (HSPA+ fallback), GPS, USB
Remote control (differs)Reports over HTTP/HTTPS to NoisePlatform; configurable remotelySoft dB Monitoring Web Service
Software (differs)NoisePlatformSoft dB Monitoring Web Service

The instruments on their own

Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.