The doseBadge (CR:130A) vs Quest Edge 7 (EG7)
Every specification Cirrus Research and TSI Quest publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.
| Specification | The doseBadge (CR:130A)Cirrus Research | Quest Edge 7 (EG7)TSI Quest |
|---|---|---|
| Status | Announced | Current |
| Verified on | ||
| Standards and class | ||
| IEC 61672-1 class (differs) | — | Class 2 |
| Standards (differs) | IEC 61252:2025, ANSI S1.25:1991 (R2007) | ANSI S1.25 (2AS-V/V-5), IEC 61252, IEC 61260-1:2014 class 2 (1/1 octave filters) |
| Measurement | ||
| Channels (differs) | — | 1 |
| Measurement range (differs) | 60 to 140 dB(A) RMS (typical) | 70 to 140 dB (RMS) |
| Peak range (differs) | 80 to 143 dB(C) (typical) | 110 to 143 dB |
| Frequency weightings | A, C, Z | A, C, Z |
| Time weightings | F, S | F, S |
| Parameters (differs) | Leq/LAVG, TWA, %Dose, Lpeak | SPL, Lavg/Leq, Lmax, Lmin, LCpeak, Exposure (Pa2h), TWA, Dose, UL time, Ceiling exceedance count, 1/1 octave bands |
| Dosimetry | Yes | Yes |
| Exchange rates (differs) | 3 dB, 4 dB, 5 dB, 6 dB | 3 dB, 4 dB, 5 dB |
| Analysis | ||
| Octave bands (differs) | — | 1/1 |
| Octave band filter class (differs) | — | class 2 (IEC 61260-1:2014); 31.5 Hz to 8 kHz, Meter 1 only |
| Audio recording (differs) | — | Yes |
| Logging and data | ||
| Shortest logging interval (differs) | — | 1 s (1, 5, 10, 15, 30 or 60 s) |
| Memory (differs) | up to 40 measurements; up to 74 h of time history; 24 h maximum single measurement | Up to 100 days of noise data at 1-minute logging (without voice notes, audio or octave data) |
| Hardware | ||
| Microphone (differs) | — | 1/2" MEMS, field-replaceable (MIC-EG7), Type 2/Class 2 |
| Detachable preamplifier (differs) | No | — |
| Display (differs) | — | 128 x 64 colour OLED |
| Battery (differs) | internal Li-Po 3.7 V 630 mAh | Lithium polymer (flat cell), charged in EdgeConnect docking station |
| Battery life (differs) | 24 h | 30 h |
| External power (differs) | charging dock | — |
| Weight (differs) | 50 g | 113 g |
| Dimensions (mm) (differs) | 47 x 47 x 44 (excluding strap); 175 x 70 x 60 (including strap) | 117 x 61 x 48 (without windscreen, including microphone) |
| IP rating (differs) | — | IP65 |
| Operating temperature (°C) | -10 to 50 | -10 to 50 |
| Connectivity and software | ||
| Connectivity (differs) | Bluetooth, USB via dock | Bluetooth LE 5 (EG7-BT), USB via EdgeConnect docking station |
| Remote control (differs) | — | Edge dB mobile app (iOS, Android) |
| Software (differs) | NoiseTools | Detection Management Software (DMS), Edge dB app |
The instruments on their own
- The doseBadge (CR:130A) — full record, sources and owner reviews
- Quest Edge 7 (EG7) — full record, sources and owner reviews
Other comparisons
- The doseBadge (CR:130A) vs Svantek SV 102A+
- The doseBadge (CR:130A) vs TES-660
- The doseBadge (CR:130A) vs Quest Edge 4+ (EG4P)
- Aihua AWA5920 vs Quest Edge 7 (EG7)
- Brüel & Kjær 4448 vs Quest Edge 7 (EG7)
- Spark 706RC vs Quest Edge 7 (EG7)
- NoiseBadge Intrinsically Safe (Model 22) vs Quest Edge 7 (EG7)
- NoiseBadge (Model 22) vs Quest Edge 7 (EG7)
Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.