SpecificationNoiseBadge (Model 22)Pulsar InstrumentsQuest Edge 7 (EG7)TSI Quest
StatusCurrentCurrent
Verified on
Manufacturer list priceGBP 510
Standards and class
IEC 61672-1 class (differs)—Class 2
Standards (differs)IEC 61252:1993, ANSI S1.25:1991, IEC 60942:2001 class 2 (reader calibrator)ANSI S1.25 (2AS-V/V-5), IEC 61252, IEC 61260-1:2014 class 2 (1/1 octave filters)
Recommended calibration interval (differs)12 months—
Measurement
Channels (differs)21
Measurement range (differs)70 to 130 dB(A) RMS70 to 140 dB (RMS)
Peak range (differs)120 to 140 dB(C)110 to 143 dB
Frequency weightings (differs)A, CA, C, Z
Time weightings (differs)SF, S
Parameters (differs)LAeq, LEP,d / LEX,8h, LAE, LCpeak, Lavg, TWA, Dose %, estimated Dose %, exposure Pa2h, 115 dB(A) exceedanceSPL, Lavg/Leq, Lmax, Lmin, LCpeak, Exposure (Pa2h), TWA, Dose, UL time, Ceiling exceedance count, 1/1 octave bands
DosimetryYesYes
Exchange rates3 dB, 4 dB, 5 dB3 dB, 4 dB, 5 dB
Analysis
Octave bands (differs)None1/1
Octave band filter class (differs)—class 2 (IEC 61260-1:2014); 31.5 Hz to 8 kHz, Meter 1 only
Reverberation time (differs)No—
Building acoustics (differs)No—
Audio recording (differs)NoYes
Logging and data
Shortest logging interval (differs)1 min1 s (1, 5, 10, 15, 30 or 60 s)
Memory (differs)reader stores up to 93 eight-hour, 64 twelve-hour or 33 twenty-four-hour measurementsUp to 100 days of noise data at 1-minute logging (without voice notes, audio or octave data)
Hardware
Microphone (differs)removable prepolarised electret, 1/2" class 21/2" MEMS, field-replaceable (MIC-EG7), Type 2/Class 2
Detachable preamplifier (differs)No—
Display (differs)none on badge (status LED); backlit LCD on reader128 x 64 colour OLED
Battery (differs)internal NiMH, about 3 h charge; reader 2 x AA or USBLithium polymer (flat cell), charged in EdgeConnect docking station
Battery life (differs)20 h30 h
Weight (differs)45 g113 g
Dimensions (mm) (differs)height 38, base diameter 47, microphone apex diameter 13117 x 61 x 48 (without windscreen, including microphone)
IP rating (differs)—IP65
Operating temperature (°C)-10 to 50-10 to 50
Connectivity and software
Connectivity (differs)infrared to reader, USB 2.0 (reader to PC)Bluetooth LE 5 (EG7-BT), USB via EdgeConnect docking station
Remote control (differs)—Edge dB mobile app (iOS, Android)
Software (differs)AnalyzerPlusDetection Management Software (DMS), Edge dB app

The instruments on their own