Skip to content
soundlevelmeter.review

BSWA 308 vs Optimus+ Environmental Sound Level Meter

Every specification BSWA Technology and Cirrus Research publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationBSWA 308BSWA TechnologyOptimus+ Environmental Sound Level MeterCirrus Research
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)GB/T 3785.1-2023, IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013 class 1, ANSI S1.4-1983, ANSI S1.43-1997, IEC 61260-1:2014, ANSI S1.11-2004, GB/T 3241.1-2025IEC 61672-1:2013 class 1 or class 2, IEC 61260 and ANSI S1.11-2004 (1:1 and 1:3 octave filters), IEC 60651, IEC 60804, ANSI S1.4, ANSI S1.43, DIN 45657
Pattern approvals (differs)—PTB (class 1), LNE (class 1)
Recommended calibration interval (differs)—12 months
Measurement
Channels11
Measurement range (differs)Single range, 123 dB dynamic range; upper limit 136 dB rms with 40 mV/Pa microphone (154 dB(A) with a 5 mV/Pa microphone)20 to 140 dB, single range
Linearity range (differs)22 dB(A) to 136 dB—
Peak range (differs)47 to 139 dB (C)—
Frequency range (differs)10 Hz to 20 kHz6.3 Hz to 20 kHz (1:3 octave bands measured; 12.5 Hz to 20 kHz displayed)
Frequency weightings (differs)A, B, C, ZA, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightingsYesYes
Parameters (differs)SPL, Leq, Leq1s, LIeq, SD, SEL, E, Lmax, Lmin, Lpeak, Lday, Levening, Lnight, Ldn, Lden, LN (1 to 99)LXeq, LXYmax, LXYmin, LCpeak, LZpeak, LXE, Ln statistics, Lden, Leq LF (20 to 200 Hz), tonal noise detection (C models)
Analysis
Octave bands1/1 and 1/31/1 and 1/3
Octave band filter class (differs)class 1—
Audio recording (differs)—Yes
Logging and data
Shortest logging interval (differs)0.1 s10 ms
Memory (differs)8 GB microSD8 GB standard; 32 GB factory option
Hardware
Microphone (differs)MPA231T 1/2" prepolarised, class 1, 40 mV/Pa (BSWA 309: MPA309T, class 2)class 1: MK:224 1/2" pre-polarised; class 2: MK:216 pre-polarised
Detachable preamplifier (differs)—Yes
Outdoor microphone kit (differs)—Outdoor Environmental Noise Kit (CK:67x/68x) with MK:172 outdoor microphone
Display (differs)160 x 160 LCD, white backlighthigh-resolution OLED with ambient light sensor and illuminated keypad
Battery (differs)4 x AA (LR6) alkaline4 x AA alkaline or lithium
Battery life (differs)10 h12 h
External power (differs)7 to 14 V DC, 500 mA, or USB 5 V, 1 A5 to 15 V DC via ZL:171 cable
Weight (differs)620 g300 g
Dimensions (mm) (differs)70 x 300 x 36283 x 65 x 30
Operating temperature (°C)-10 to 50-10 to 50
Connectivity and software
Connectivity (differs)USB, RS-232, AC output, DC output, microSD, GPS module (optional)USB type B, Bluetooth Low Energy, AC/DC output, GPS (GPS model)
Remote control (differs)—MyCirrus mobile apps via Bluetooth; remote access via Outdoor Kit modem
Software (differs)VA-SLMNoiseTools, MyCirrus app

The instruments on their own

Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.