doseBadge5 Personal Noise Dosimeter (CR:120A) vs Spartan 730
Every specification Cirrus Research and Larson Davis publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.
| Specification | doseBadge5 Personal Noise Dosimeter (CR:120A)Cirrus Research | Spartan 730Larson Davis |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| Standards (differs) | IEC 61252:1993 +AMD1:2000 (Ed 1.1, 2002-03), ANSI S1.25:1991 (R2017), IEC 61260-1:2014 class 2 and ANSI S1.11-2014 class 2 (octave bands) | ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2, ANSI/ASA S1.11-2014 and IEC 61260-1:2014 class 1 (optional filters) |
| Measurement | ||
| Channels (differs) | 6 | 1 |
| Measurement range (differs) | 60 to 140 dB(A) RMS; linear operating range 65 to 140 dB(A) | 52 to 140 dB rms A-weighted (linear operating range); dynamic range 94 dB |
| Linearity range (differs) | 65 to 140 dB(A) | 52 to 140 dB(A) |
| Peak range (differs) | 80 to 143 dB(C) | 78 to 143 dB peak, C-weighted |
| Frequency range (differs) | 63 Hz to 8 kHz (octave bands) | 20 Hz to 10 kHz |
| Frequency weightings | A, C, Z | A, C, Z |
| Time weightings (differs) | F, S | F, S, I |
| Simultaneous weightings (differs) | Yes | — |
| Parameters (differs) | Leq/LAVG, LEP,d / LEX,8h / TWA, %Dose and estimated %Dose, Lpeak, sound exposure, ULT duration, SPL max and min, LCeq-LAeq (HML) | Dose, ProjDose, Lavg, TWA(8), Proj TWA(8), Lex,8h, Lep,d, LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, LC-A, exposure Pa2s and Pa2h, motion |
| Dosimetry | Yes | Yes |
| Exchange rates (differs) | 3 dB, 4 dB, 5 dB | 3 dB, 4 dB, 5 dB, 6 dB |
| Analysis | ||
| Octave bands | 1/1 | 1/1 |
| Octave band filter class (differs) | class 2 (IEC 61260-1:2014) | class 1 (IEC 61260-1:2014), 31.5 Hz to 8 kHz, option 730-OB1 |
| Reverberation time (differs) | — | No |
| Building acoustics (differs) | — | No |
| Audio recording (differs) | — | Yes |
| Logging and data | ||
| Shortest logging interval | 1 s | 1 s |
| Memory (differs) | up to 80 h of time history (6 channels); up to 40 measurements; 24 h maximum single measurement | 32 GB internal |
| Hardware | ||
| Microphone (differs) | — | 1/4" Model 375A03 |
| Detachable preamplifier | No | No |
| Display (differs) | none | colour LCD 176 x 176 pixels, always on, with light sensor and front light |
| Battery (differs) | internal NiMH | rechargeable lithium-ion; Qi wireless or USB charging, 3 h charge time |
| Battery life (differs) | 20 h | 40 h |
| External power (differs) | charging dock (3 h from empty) | — |
| Weight (differs) | 85 g | 112 g |
| Dimensions (mm) (differs) | 66 x 43 x 53 (excluding clips) | 85 x 54 x 39 |
| IP rating (differs) | — | IP65 |
| Operating temperature (°C) | -10 to 50 | -10 to 50 |
| Connectivity and software | ||
| Connectivity (differs) | Bluetooth, USB via charging dock | Bluetooth LE 4.1, USB 2.0 Micro-B |
| Remote control (differs) | doseBadge5 remote control wand; dBLink / MyCirrus app (iOS, Android) | LD Atlas app (iOS and Android) |
| Software (differs) | NoiseTools, dBLink app | LD Atlas, G4 LD Utility |
The instruments on their own
- doseBadge5 Personal Noise Dosimeter (CR:120A) — full record, sources and owner reviews
- Spartan 730 — full record, sources and owner reviews
Other comparisons
- dBadge CEL-35x vs doseBadge5 Personal Noise Dosimeter (CR:120A)
- dBadge CEL-35x vs Spartan 730
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs NoiseBadge (Model 22)
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs Svantek SV 102A+
- Spartan 730 vs Svantek SV 102A+
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs TES-660
- Spartan 730 vs TES-660
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs Quest Edge 4+ (EG4P)
Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.