Skip to content
soundlevelmeter.review

doseBadge5 Personal Noise Dosimeter (CR:120A) vs Svantek SV 102A+

Every specification Cirrus Research and Svantek publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationdoseBadge5 Personal Noise Dosimeter (CR:120A)Cirrus ResearchSvantek SV 102A+Svantek
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 class (differs)—Class 1
Standards (differs)IEC 61252:1993 +AMD1:2000 (Ed 1.1, 2002-03), ANSI S1.25:1991 (R2017), IEC 61260-1:2014 class 2 and ANSI S1.11-2014 class 2 (octave bands)IEC 61252, ANSI S1.25-1991, IEC 61672-1:2013 class 1, ISO 11904-1 (MIRE), ISO 9612
Measurement
Channels (differs)62
Measurement range (differs)60 to 140 dB(A) RMS; linear operating range 65 to 140 dB(A)—
Linearity range (differs)65 to 140 dB(A)45 dB(A) Leq to 141 dB(A) peak
Peak range (differs)80 to 143 dB(C)up to 141 dB(A) peak
Frequency range (differs)63 Hz to 8 kHz (octave bands)20 Hz to 20 kHz
Frequency weightingsA, C, ZA, C, Z
Time weightings (differs)F, SF, S, I
Simultaneous weightings (differs)Yes—
Parameters (differs)Leq/LAVG, LEP,d / LEX,8h / TWA, %Dose and estimated %Dose, Lpeak, sound exposure, ULT duration, SPL max and min, LCeq-LAeq (HML)Dose, TWA 8h, LEX,8h, LEP,d, statistics in octaves or third octaves
DosimetryYesYes
Exchange rates (differs)3 dB, 4 dB, 5 dB—
Analysis
Octave bands (differs)1/11/1 and 1/3
Octave band filter class (differs)class 2 (IEC 61260-1:2014)optional (1/3 octave required for MIRE)
Reverberation time (differs)—No
Building acoustics (differs)—No
Audio recording (differs)—Yes
Logging and data
Shortest logging interval (differs)1 s—
Memory (differs)up to 80 h of time history (6 channels); up to 40 measurements; 24 h maximum single measurement32 GB
Hardware
Microphone (differs)—2 x 1/2" ACO SV 7052E prepolarised with SV 15 preamplifiers; SV 25S MIRE probe microphone optional
Detachable preamplifier (differs)NoYes
Display (differs)noneDisplay with 4 buttons (type not stated)
Battery (differs)internal NiMH2 x AA alkaline
Battery life (differs)20 h16 h
External power (differs)charging dock (3 h from empty)—
Weight (differs)85 g260 g
Dimensions (mm) (differs)66 x 43 x 53 (excluding clips)95 x 83 x 33
Operating temperature (°C)-10 to 50-10 to 50
Connectivity and software
Connectivity (differs)Bluetooth, USB via charging dockUSB via docking station, Bluetooth
Remote control (differs)doseBadge5 remote control wand; dBLink / MyCirrus app (iOS, Android)—
Software (differs)NoiseTools, dBLink appSupervisor

The instruments on their own

Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.