| Specification | Original doseBadge (CR:110A)Cirrus Research | TSI OmniWear Noise (OW-N-DVE)TSI Quest |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| Standards (differs) | IEC 61252:1993, ANSI S1.25:1991 class 2AS-90/80-5, IEC 60942:2003 class 2 (Reader Unit calibrator) | IEC 61252:1997 + A2:2017 (BS EN), ANSI S1.25:1991 (R2024) |
| Measurement | ||
| Channels (differs) | 2 | 1 |
| Measurement range (differs) | 70 to 130 dB(A) RMS | 70 to 140.3 dB(A) RMS (linear operating range) |
| Linearity range (differs) | — | 70 to 140.3 dB(A) |
| Peak range (differs) | 120 to 140 dB(C) | 90.0 to 143.3 dB (C or Z weighted) |
| Frequency weightings (differs) | A, C | A, C, Z |
| Time weightings (differs) | S | F, S, I |
| Parameters (differs) | LAeq, LEX,8h / Lep,d, LAE, %Dose and estimated %Dose, exposure (Pa2h), LAVG, TWA, LCpeak | LXY, LXYmax, LXeq, LXpeak, Lavg, LXIeq, LTM3, LTM5, LAE, LAep,d, LEX,8h, TWA, Dose % (incl. projected), Pa2h, Pa2s, Motion %, time above threshold |
| Dosimetry | Yes | Yes |
| Exchange rates (differs) | 3 dB, 4 dB, 5 dB | 3 dB, 5 dB |
| Intrinsically safe marking (differs) | CR:110AIS only: Baseefa04ATEX0330 Ex II 1 G Ex ia IIC T4 Ga; Baseefa04ATEX0331X Ex I M1 Ex ia I Ma; IECEx BAS 06.0084 and 06.0083X; BAS21UKEX0374 and 0375X; FM IS/I/1/ABCD/T4; MSHA 18-A060027-0; IP54 | — |
| Analysis | ||
| Octave bands (differs) | None | — |
| Logging and data | ||
| Shortest logging interval (differs) | 1 min | 1 s |
| Memory (differs) | up to 24 h in a single measurement; Reader Unit stores up to 999 measurements | 64 runs maximum |
| Hardware | ||
| Microphone (differs) | — | MEMS microphone |
| Detachable preamplifier (differs) | No | — |
| Display (differs) | none (display on Reader Unit) | none (multifunction LED status indicator and one action button) |
| Battery (differs) | internal NiMH; Reader Unit 2 x AA | Rechargeable Li-ion 350 mAh; wireless drop-in charger (4 h to 85 %, 6 h to 100 %) |
| Battery life (differs) | 24 h | 16 h |
| External power (differs) | charging via Reader Unit (about 90 min) | — |
| Weight (differs) | 51 g | 36 g |
| Dimensions (mm) (differs) | height 38; microphone apex diameter 13; base diameter 7 | 56 x 32 x 40 |
| IP rating (differs) | IP54 (IS version, FM listing) | IP65 |
| Operating temperature (°C) (differs) | -10 to 50 | 0 to 40 (< +/-0.5 dB error); -10 to 50 (< +/-0.8 dB error) |
| Connectivity and software | ||
| Connectivity (differs) | infrared to Reader Unit, USB 2.0 (Reader Unit) | Bluetooth |
| Remote control (differs) | RC:110A Reader Unit | OmniWear Noise app (iOS, Android) |
| Software (differs) | NoiseTools | OmniWear Noise app |
The instruments on their own
- Original doseBadge (CR:110A) — full record, sources and owner reviews
- TSI OmniWear Noise (OW-N-DVE) — full record, sources and owner reviews
Other comparisons
- Original doseBadge (CR:110A) vs Spartan 730
- Spartan 730 vs TSI OmniWear Noise (OW-N-DVE)
- Original doseBadge (CR:110A) vs Svantek SV 102A+
- Svantek SV 102A+ vs TSI OmniWear Noise (OW-N-DVE)
- Original doseBadge (CR:110A) vs TES-660
- Original doseBadge (CR:110A) vs Quest Edge 4+ (EG4P)
- Original doseBadge (CR:110A) vs Quest Edge 5 (EG5)
- dBadge2 vs TSI OmniWear Noise (OW-N-DVE)
Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.