Every specification Larson Davis and TSI Quest publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.
| Specification | Spartan 730Larson Davis | TSI OmniWear Noise (OW-N-DVE)TSI Quest |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Standards and class | ||
| Standards (differs) | ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2, ANSI/ASA S1.11-2014 and IEC 61260-1:2014 class 1 (optional filters) | IEC 61252:1997 + A2:2017 (BS EN), ANSI S1.25:1991 (R2024) |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | 52 to 140 dB rms A-weighted (linear operating range); dynamic range 94 dB | 70 to 140.3 dB(A) RMS (linear operating range) |
| Linearity range (differs) | 52 to 140 dB(A) | 70 to 140.3 dB(A) |
| Peak range (differs) | 78 to 143 dB peak, C-weighted | 90.0 to 143.3 dB (C or Z weighted) |
| Frequency range (differs) | 20 Hz to 10 kHz | — |
| Frequency weightings | A, C, Z | A, C, Z |
| Time weightings | F, S, I | F, S, I |
| Parameters (differs) | Dose, ProjDose, Lavg, TWA(8), Proj TWA(8), Lex,8h, Lep,d, LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, LC-A, exposure Pa2s and Pa2h, motion | LXY, LXYmax, LXeq, LXpeak, Lavg, LXIeq, LTM3, LTM5, LAE, LAep,d, LEX,8h, TWA, Dose % (incl. projected), Pa2h, Pa2s, Motion %, time above threshold |
| Dosimetry | Yes | Yes |
| Exchange rates (differs) | 3 dB, 4 dB, 5 dB, 6 dB | 3 dB, 5 dB |
| Analysis | ||
| Octave bands (differs) | 1/1 | — |
| Octave band filter class (differs) | class 1 (IEC 61260-1:2014), 31.5 Hz to 8 kHz, option 730-OB1 | — |
| Reverberation time (differs) | No | — |
| Building acoustics (differs) | No | — |
| Audio recording (differs) | Yes | — |
| Logging and data | ||
| Shortest logging interval | 1 s | 1 s |
| Memory (differs) | 32 GB internal | 64 runs maximum |
| Hardware | ||
| Microphone (differs) | 1/4" Model 375A03 | MEMS microphone |
| Detachable preamplifier (differs) | No | — |
| Display (differs) | colour LCD 176 x 176 pixels, always on, with light sensor and front light | none (multifunction LED status indicator and one action button) |
| Battery (differs) | rechargeable lithium-ion; Qi wireless or USB charging, 3 h charge time | Rechargeable Li-ion 350 mAh; wireless drop-in charger (4 h to 85 %, 6 h to 100 %) |
| Battery life (differs) | 40 h | 16 h |
| Weight (differs) | 112 g | 36 g |
| Dimensions (mm) (differs) | 85 x 54 x 39 | 56 x 32 x 40 |
| IP rating | IP65 | IP65 |
| Operating temperature (°C) (differs) | -10 to 50 | 0 to 40 (< +/-0.5 dB error); -10 to 50 (< +/-0.8 dB error) |
| Connectivity and software | ||
| Connectivity (differs) | Bluetooth LE 4.1, USB 2.0 Micro-B | Bluetooth |
| Remote control (differs) | LD Atlas app (iOS and Android) | OmniWear Noise app (iOS, Android) |
| Software (differs) | LD Atlas, G4 LD Utility | OmniWear Noise app |
The instruments on their own
- Spartan 730 — full record, sources and owner reviews
- TSI OmniWear Noise (OW-N-DVE) — full record, sources and owner reviews
Other comparisons
- dBadge CEL-35x vs Spartan 730
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs Spartan 730
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs TSI OmniWear Noise (OW-N-DVE)
- Original doseBadge (CR:110A) vs Spartan 730
- Original doseBadge (CR:110A) vs TSI OmniWear Noise (OW-N-DVE)
- Spartan 730 vs Rion NB-14
- Spartan 730 vs Svantek SV 102A+
- Svantek SV 102A+ vs TSI OmniWear Noise (OW-N-DVE)
Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.