Every specification Larson Davis and TSI Quest publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.
| Specification | Spark 706RCLarson Davis | Quest Edge 4+ (EG4P)TSI Quest |
|---|---|---|
| Status | Discontinued | Current |
| Verified on | ||
| Standards and class | ||
| Standards (differs) | — | ANSI S1.25 (personal noise dosimeters), IEC 61252 (personal sound exposure meters) |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | 40 to 143 dB rms in four ranges | 70 to 140 dB |
| Peak range (differs) | 80 to 146 dB in four ranges | 110 to 143 dB |
| Frequency weightings (differs) | A, C | A, C, Z |
| Time weightings | F, S | F, S |
| Parameters (differs) | Leq, Lmax, Lpeak, Lmin, four time-weighted averages, Ln (1 to 99), Dose, projected Dose, SE (Pa2h), SEA | Lavg, Leq, SPL, Lmax, Lmin, SEL (LEP), Dose, TWA, Lpeak, exposure, time above threshold, upper limit time |
| Dosimetry | Yes | Yes |
| Exchange rates (differs) | 3 dB, 4 dB, 5 dB, 6 dB | 3 dB, 4 dB, 5 dB |
| Analysis | ||
| Octave bands | None | None |
| Reverberation time (differs) | No | — |
| Building acoustics (differs) | No | — |
| Audio recording (differs) | No | — |
| Logging and data | ||
| Shortest logging interval (differs) | 1 s | 1 min |
| Memory (differs) | 4 MB non-volatile | 180 hours |
| Hardware | ||
| Microphone (differs) | 3/8" (10.6 mm) MPR001 integrated microphone/preamplifier on 1 m cable | 1/4" prepolarised condenser (electret), threaded, field-replaceable |
| Detachable preamplifier (differs) | No | — |
| Display (differs) | LCD with backlight (706RC only) | 128 x 64 colour OLED with configurable auto shut-off |
| Battery (differs) | 2 x AA alkaline, NiCd or NiMH | Lithium polymer flat cell; charged in EdgeDock (2 to 4 h) |
| Battery life (differs) | 100 h | 20 h |
| Weight (differs) | — | 85 g |
| Dimensions (mm) (differs) | — | 88 x 53 x 19 |
| IP rating (differs) | — | IP65 |
| Operating temperature (°C) (differs) | — | -10 to 50; storage -25 to 60 |
| Connectivity and software | ||
| Connectivity (differs) | infrared (DVX010 USB-to-IR module) | Bluetooth (optional), USB via docking station |
| Remote control (differs) | — | Edge dB mobile app (iOS, Android) |
| Software (differs) | Blaze | Detection Management Software (DMS), Edge dB app |
The instruments on their own
- Spark 706RC — full record, sources and owner reviews
- Quest Edge 4+ (EG4P) — full record, sources and owner reviews
Other comparisons
- Spark 706RC vs Quest Edge 7 (EG7)
- Spark 706RC vs Quest Edge 8 (EG8)
- Spark 706RC vs TSI OmniWear Noise (OW-N-DVE)
- dBadge CEL-35x vs Quest Edge 4+ (EG4P)
- dBadge2 vs Quest Edge 4+ (EG4P)
- The doseBadge (CR:130A) vs Quest Edge 4+ (EG4P)
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs Quest Edge 4+ (EG4P)
- Original doseBadge (CR:110A) vs Quest Edge 4+ (EG4P)
Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.