NoisePen vs Svantek SV 104BIS
Every specification Pulsar Instruments and Svantek publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.
| Specification | NoisePenPulsar Instruments | Svantek SV 104BISSvantek |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Manufacturer list price | GBP 510 | |
| Standards and class | ||
| IEC 61672-1 class | Class 2 | Class 2 |
| Standards (differs) | IEC 61252:1993, ANSI S1.25:1991, IEC 61000-6-1:2007 and IEC 61000-6-3:2007 (EMC) | IEC 61252 Ed 1.2 (R2017), ANSI/ASA S1.25-1991 (R2024), IEC 61672-1:2013 class 2, ISO 9612 |
| Recommended calibration interval (differs) | 12 months | — |
| Measurement | ||
| Channels | 1 | 1 |
| Measurement range (differs) | 70 to 140 dB(A) | 46 dB(A) RMS to 143 dB(A) peak (total range) |
| Linearity range (differs) | — | 53 dB(A) RMS to 143 dB(A) peak |
| Peak range (differs) | 90 to 143 dB(C) | up to 143 dB peak |
| Frequency range (differs) | — | 20 Hz to 10 kHz |
| Frequency weightings | A, C, Z | A, C, Z |
| Time weightings (differs) | F, S | F, S, I |
| Simultaneous weightings (differs) | — | Yes |
| Parameters (differs) | LAeq, LEP,d / LEX,8h, LCpeak, LZpeak, TWA, Dose % | Leq, Lmax, Lmin, Lpeak, Dose, TWA, Lav, four parallel profiles |
| Dosimetry | Yes | Yes |
| Exchange rates (differs) | — | 2 dB, 3 dB, 4 dB, 5 dB, 6 dB |
| Intrinsically safe marking (differs) | — | ATEX and IECEx certified (marking codes not published on the product page) |
| Analysis | ||
| Octave bands (differs) | None | 1/1 and 1/3 |
| Octave band filter class (differs) | — | optional licences SF 104BIS_OCT and SF 104BIS_3OCT |
| Reverberation time | No | No |
| Building acoustics | No | No |
| Audio recording (differs) | No | Yes |
| Logging and data | ||
| Shortest logging interval | 1 s | 1 s |
| Memory (differs) | 20 eight-hour shifts at 1 s storage (about 160 h) | 8 GB |
| Hardware | ||
| Microphone (differs) | removable prepolarised 1/2" electret, class 2 | MEMS ST 104B with integrated preamplifier and TEDS auto-calibration |
| Detachable preamplifier | No | No |
| Display (differs) | none; status LED | Display with 3 push buttons (type not stated) |
| Battery (differs) | internal 1.2 V NiMH pack, USB 5 V charging, under 4 h | Rechargeable Li-ion cell |
| Battery life (differs) | 30 h | 45 h |
| Weight (differs) | 82 g | 117 g |
| Dimensions (mm) (differs) | 124 x 34 x 28 (excluding windshield) | 88 x 49.5 x 19.2 |
| IP rating (differs) | — | IP65 |
| Operating temperature (°C) (differs) | 0 to 40 | -10 to 50 |
| Connectivity and software | ||
| Connectivity (differs) | mini-USB | Bluetooth, electrical contacts via docking station |
| Remote control (differs) | — | Assistant app (results preview and alarms) |
| Software (differs) | AnalyzerPlus | Assistant app, Supervisor |