SpecificationPiccolo IISoft dBTES-1150TES Electrical Electronic
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 2Class 2
Standards (differs)IEC 61672-1:2013 class 2, group X, ANSI/ASA S1.4-1:2014 class 2, ANSI S1.43:2007 type 2, IEC 60651 type 2, IEC 61260-1 class 2 and ANSI S1.11 class 2 (1/1 octave)IEC 61672-1:2013 class 2, ANSI S1.4:1983 type 2
Measurement
Channels11
Measurement range (differs)Low range 30 dBA to 110 dB peak; high range 46 dBA to 130 dB peak30-90, 45-110, 65-130 dB
Peak range (differs)110 dBZpk (low range), 130 dBZpk (high range)65-93.4, 85-113.4, 105-133.4 dB
Frequency range (differs)20 Hz to 16 kHz31.5 Hz to 8 kHz (typical)
Frequency weightingsA, C, ZA, C, Z
Time weightings (differs)F, SF, S, I
Parameters (differs)Leq, Lmax, Lmin, Lpeak, SEL, LN (1, 2, 5, 8, 10, 25, 50, 90, 95, 99 %)Sound level, Peak hold (A, C, Z), Maximum hold
Analysis
Octave bands (differs)1/1 and 1/3None
Octave band filter class (differs)1/1 octave class 2 (IEC 61260-1, ANSI S1.11), 31.5 Hz to 8 kHz; 1/3 octave 20 Hz to 16 kHz in PC software only (group Z)—
FFT (differs)400 lines, 6 bandwidths from 17.2 kHz down to 539 Hz—
Audio recording (differs)Yes—
Logging and data
Shortest logging interval (differs)1 s—
Memory (differs)198,948 records without FFT; 18,798 records with FFT—
Hardware
Microphone (differs)1/2" microphone, nominal sensitivity -35 dB re 1 V/Pa (17.78 mV/Pa); type not stated1/2" electret condenser
Display (differs)—4 digit LCD
Battery (differs)Embedded lithium battery, USB charged (5 V)9 V (006P / 6F22)
Battery life (differs)48 h24 h
Weight (differs)115 g180 g
Dimensions (mm) (differs)144 x 59 x 18.5246 x 64 x 26
Operating temperature (°C) (differs)0 to 40-10 to 50
Connectivity and software
Connectivity (differs)USB (micro-B), 3.5 mm auxiliary inputAC output, DC output
Software (differs)Piccolo II control and post-processing software—

The instruments on their own