Skip to content
soundlevelmeter.review

Bedrock SM90 vs Optimus+ Environmental Sound Level Meter

Every specification Bedrock and Cirrus Research publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationBedrock SM90BedrockOptimus+ Environmental Sound Level MeterCirrus Research
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1:2014 group X class 1, ANSI S1.4 type 1, IEC 60268-16 rev. 4 (2011) and rev. 5 (2020), IEC 61260:2014, ISO 3382-2, ANSI S12.2, ISO 1996IEC 61672-1:2013 class 1 or class 2, IEC 61260 and ANSI S1.11-2004 (1:1 and 1:3 octave filters), IEC 60651, IEC 60804, ANSI S1.4, ANSI S1.43, DIN 45657
Pattern approvals (differs)—PTB (class 1), LNE (class 1)
Recommended calibration interval (differs)—12 months
Measurement
Channels (differs)—1
Measurement range (differs)30 to 122 dB with the included microphone; electronics > 110 dB combined ranges20 to 140 dB, single range
Linearity range (differs)26 to 118 dB (low range); 42 to 124 dB (high range), Z-weighted—
Peak range (differs)up to 124 dB (highest range, 20 Hz to 20 kHz)—
Frequency range (differs)20 Hz to 20 kHz6.3 Hz to 20 kHz (1:3 octave bands measured; 12.5 Hz to 20 kHz displayed)
Frequency weightingsA, C, ZA, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightings (differs)—Yes
Parameters (differs)Leq, SEL, Lmax, Lpeak, L10, L90 and other percentiles, STI, RT60, Dn, R', DnT, L'nTLXeq, LXYmax, LXYmin, LCpeak, LZpeak, LXE, Ln statistics, Lden, Leq LF (20 to 200 Hz), tonal noise detection (C models)
Analysis
Octave bands1/1 and 1/31/1 and 1/3
Octave band filter class (differs)exceeds class 1 (IEC 61260:2014); 1/6 and 1/12 octave also available—
FFT (differs)FFT analyser (line count not published)—
Reverberation time (differs)Yes—
Building acoustics (differs)Yes—
Speech intelligibility (differs)STIPA and Full STI—
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)—10 ms
Memory (differs)8 GB internal8 GB standard; 32 GB factory option
Hardware
Microphone (differs)BAMT1-MP201 1/2" free-field, class 1, XLR 48 V phantom, 50 mV/Paclass 1: MK:224 1/2" pre-polarised; class 2: MK:216 pre-polarised
Detachable preamplifierYesYes
Outdoor microphone kit (differs)—Outdoor Environmental Noise Kit (CK:67x/68x) with MK:172 outdoor microphone
Display (differs)3.2" resistive colour touch LCD, 320 x 240high-resolution OLED with ambient light sensor and illuminated keypad
Battery (differs)NiMH pack, 4.8 V, 2500 mAh4 x AA alkaline or lithium
Battery life (differs)4 h12 h
External power (differs)—5 to 15 V DC via ZL:171 cable
Weight (differs)530 g300 g
Dimensions (mm) (differs)210 x 85 x 55 (excluding microphone)283 x 65 x 30
Operating temperature (°C) (differs)5 to 35-10 to 50
Connectivity and software
Connectivity (differs)USBUSB type B, Bluetooth Low Energy, AC/DC output, GPS (GPS model)
Remote control (differs)remote-control API over USBMyCirrus mobile apps via Bluetooth; remote access via Outdoor Kit modem
Software (differs)Bedrock Elite Analyzer, Bedrock StudioNoiseTools, MyCirrus app

The instruments on their own

Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.