Skip to content
soundlevelmeter.review

Optimus+ Environmental Sound Level Meter vs Svantek SV 977D

Every specification Cirrus Research and Svantek publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationOptimus+ Environmental Sound Level MeterCirrus ResearchSvantek SV 977DSvantek
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1:2013 class 1 or class 2, IEC 61260 and ANSI S1.11-2004 (1:1 and 1:3 octave filters), IEC 60651, IEC 60804, ANSI S1.4, ANSI S1.43, DIN 45657IEC 61672-1:2013 class 1, IEC 61260-1:2014 class 1, ISO 20816-1 (vibration), IEC 60268-16 (STIPA option), ISO 16283 (building acoustics app)
Pattern approvals (differs)PTB (class 1), LNE (class 1)Type approved to IEC 61672-1 class 1 (bodies not named on page)
Recommended calibration interval (differs)12 months—
Measurement
Channels11
Measurement range (differs)20 to 140 dB, single range16 dB(A) Leq to 140 dB(A) peak (total range)
Linearity range (differs)—23 dB(A) Leq to 140 dB(A) peak
Peak range (differs)—up to 140 dB(A) peak
Frequency range (differs)6.3 Hz to 20 kHz (1:3 octave bands measured; 12.5 Hz to 20 kHz displayed)3 Hz to 20 kHz; to 40 kHz with ultrasound option
Frequency weightings (differs)A, C, ZA, B, C, Z, U
Time weightingsF, S, IF, S, I
Simultaneous weightingsYesYes
Parameters (differs)LXeq, LXYmax, LXYmin, LCpeak, LZpeak, LXE, Ln statistics, Lden, Leq LF (20 to 200 Hz), tonal noise detection (C models)Leq, SPL, Lmax, Lmin, Lpeak, SEL, Ln (L1 to L99), three parallel profiles
Analysis
Octave bands1/1 and 1/31/1 and 1/3
Octave band filter class (differs)—class 1 (IEC 61260-1:2014)
FFT (differs)—option (line count not stated on page)
Reverberation time (differs)—Yes
Building acoustics (differs)—Yes
Speech intelligibility (differs)—STIPA (option)
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)10 ms2 ms
Memory (differs)8 GB standard; 32 GB factory option32 GB microSD
Hardware
Microphone (differs)class 1: MK:224 1/2" pre-polarised; class 2: MK:216 pre-polarised1/2" Microtech Gefell MK 255 with SV 12L preamplifier
Detachable preamplifierYesYes
Outdoor microphone kit (differs)Outdoor Environmental Noise Kit (CK:67x/68x) with MK:172 outdoor microphoneIP65 outdoor case with microphone protection and optional 4G modem (SV 277 PRO configuration)
Weather sensors (differs)—Yes
Display (differs)high-resolution OLED with ambient light sensor and illuminated keypadColour display with 9-key keypad (size not stated)
Battery (differs)4 x AA alkaline or lithium4 x AA rechargeable
Battery life12 h12 h
External power (differs)5 to 15 V DC via ZL:171 cable—
Weight (differs)300 g600 g
Dimensions (mm) (differs)283 x 65 x 30343 x 79 x 39
Operating temperature (°C)-10 to 50-10 to 50
Connectivity and software
Connectivity (differs)USB type B, Bluetooth Low Energy, AC/DC output, GPS (GPS model)USB-C, RS-232, I/O, Bluetooth 5.2, GPS
Remote control (differs)MyCirrus mobile apps via Bluetooth; remote access via Outdoor Kit modemSvanNET (with 4G outdoor kit); Building Acoustics PRO app
Software (differs)NoiseTools, MyCirrus appSvanPC++, Supervisor, SvanNET, Building Acoustics PRO app

The instruments on their own

Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.