Skip to content
soundlevelmeter.review

Quantum Indoor (CR:900 / CR:901) vs NMS-SE 831C

Every specification Cirrus Research and Larson Davis publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationQuantum Indoor (CR:900 / CR:901)Cirrus ResearchNMS-SE 831CLarson Davis
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1:2013 class 1 (CR:901) or class 2 (CR:900), IEC 61260:1995 (1:1 and 1:3 octave band filters), ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), ANSI S1.11-2004, EN 61000-6-3:2007+A1:2011, EN 61000-6-1:2007IEC 61672-1:2013 class 1 (831C), ANSI S1.4-2014 class 1 (831C)
Measurement
Channels11
Measurement range (differs)20 to 140 dB RMS, single range—
Frequency range (differs)6.3 Hz to 20 kHz (1:3 octave bands)—
Frequency weightingsA, C, ZA, C, Z
Time weightingsF, S, IF, S, I
Simultaneous weightings (differs)Yes—
Parameters (differs)LAeq, LCeq, LZeq, LCeq-LAeq, LAE, LEX,8h, LAFmax, LASmax, LCpeak, LAF1, LAF5, LAF10, LAF50, LAF95, LAF99, LAeq,T1 and LAeq,T2Leq, Lmax, Lmin, Lpeak, Ln, Ldn, Lden
Analysis
Octave bands (differs)1/1 and 1/3—
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)10 ms—
Memory (differs)4 GB standard (about 30 days of measurement data or 24 h of standard audio)2 GB internal (831C), expandable via USB
Hardware
Microphone (differs)MK:224 pre-polarised—
Detachable preamplifier (differs)—Yes
Weather sensors (differs)No—
Display (differs)none831C colour touch screen
Battery (differs)—8 x D-cell battery pack
External power (differs)PoE IEEE 802.3af (37 to 57 V DC), approx. 5 Wbattery pack
Autonomy on internal power (differs)—7 days
Weight (differs)1200 g—
Dimensions (mm) (differs)127 x 360 x 66—
Operating temperature (°C) (differs)-10 to 50—
Connectivity and software
Connectivity (differs)Ethernet, WiFi 2.4 and 5 GHz, BluetoothUSB
Remote control (differs)MyCirrus cloud platform (Quantum portal) and MyCirrus mobile app—
Software (differs)MyCirrus, NoiseTools, MyCirrus appG4 LD Utility

The instruments on their own