Skip to content
soundlevelmeter.review

Quantum Indoor (CR:900 / CR:901) vs NoiseLog_mobil

Every specification Cirrus Research and Sinus Messtechnik publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationQuantum Indoor (CR:900 / CR:901)Cirrus ResearchNoiseLog_mobilSinus Messtechnik
StatusCurrentCurrent
Verified on
Standards and class
IEC 61672-1 classClass 1Class 1
Standards (differs)IEC 61672-1:2013 class 1 (CR:901) or class 2 (CR:900), IEC 61260:1995 (1:1 and 1:3 octave band filters), ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), ANSI S1.11-2004, EN 61000-6-3:2007+A1:2011, EN 61000-6-1:2007IEC 61672 class 1, IEC 60651, IEC 60804, IEC 61260 class 0 (filters), MIL-STD 810F (shock)
Pattern approvals (differs)—PTB 21.21 / 13.05, METAS CH-A3-15103-00
Measurement
Channels (differs)18
Measurement range (differs)20 to 140 dB RMS, single rangedynamic range 120 dB
Frequency range (differs)6.3 Hz to 20 kHz (1:3 octave bands)DC to 40 kHz at 8 channels (80 kHz optional)
Frequency weightingsA, C, ZA, C, Z
Time weightings (differs)F, S, I—
Simultaneous weightings (differs)Yes—
Parameters (differs)LAeq, LCeq, LZeq, LCeq-LAeq, LAE, LEX,8h, LAFmax, LASmax, LCpeak, LAF1, LAF5, LAF10, LAF50, LAF95, LAF99, LAeq,T1 and LAeq,T2Lp, Lpeak, Leq (A, C, Z)
Analysis
Octave bands (differs)1/1 and 1/31/3
Octave band filter class (differs)—class 0 (IEC 61260)
FFT (differs)—FFT analysis (line count not stated on page)
Audio recordingYesYes
Logging and data
Shortest logging interval (differs)10 ms—
Memory (differs)4 GB standard (about 30 days of measurement data or 24 h of standard audio)500 GB HDD or SSD; SD/SDXC
Hardware
Microphone (differs)MK:224 pre-polarisedoutdoor microphones such as 41AN, WME952, MM255 with WS1, 46AE with RA0153
Detachable preamplifier (differs)—Yes
Outdoor microphone kit (differs)—telescoping MIL masts; optional pneumatic mast
Weather sensors (differs)NoYes
Display (differs)none10.4" TFT 1024 x 768 touch screen
Battery (differs)—internal battery, up to 15 to 16 h UPS; trailer with batteries and charger
External power (differs)PoE IEEE 802.3af (37 to 57 V DC), approx. 5 W100 to 240 V AC or 10 to 36 V DC; trailer 230 V AC / 24 V DC on-board supply
Autonomy on internal power (differs)—7 days
Weight (differs)1200 g6000 g
Dimensions (mm) (differs)127 x 360 x 66500 x 400 x 220 (case; Soundbook spec gives 600 x 400 x 220)
IP rating (differs)—IP65 (case); IP54 (PC and trailer)
Operating temperature (°C)-10 to 50-10 to 50
Connectivity and software
Connectivity (differs)Ethernet, WiFi 2.4 and 5 GHz, BluetoothLAN, WLAN, GPRS, Bluetooth, modem RJ-11, optional 3G/4G/LTE router, alarm relay outputs
Remote control (differs)MyCirrus cloud platform (Quantum portal) and MyCirrus mobile appfull remote control over network; MUNISENSE web platform; e-mail and relay alarms
Software (differs)MyCirrus, NoiseTools, MyCirrus appSAMURAI, Auditor, MUNISENSE

The instruments on their own

Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.