Skip to content
soundlevelmeter.review

doseBadge5 Personal Noise Dosimeter (CR:120A) vs TSI OmniWear Noise (OW-N-DVE)

Every specification Cirrus Research and TSI Quest publish for these two instruments, side by side. Rows where the values differ are tinted. A blank cell means that manufacturer does not publish the figure, which is itself worth knowing. Nothing here is written by either manufacturer.

Side-by-side specifications. Rows where the instruments differ have a tinted background.
SpecificationdoseBadge5 Personal Noise Dosimeter (CR:120A)Cirrus ResearchTSI OmniWear Noise (OW-N-DVE)TSI Quest
StatusCurrentCurrent
Verified on
Standards and class
Standards (differs)IEC 61252:1993 +AMD1:2000 (Ed 1.1, 2002-03), ANSI S1.25:1991 (R2017), IEC 61260-1:2014 class 2 and ANSI S1.11-2014 class 2 (octave bands)IEC 61252:1997 + A2:2017 (BS EN), ANSI S1.25:1991 (R2024)
Measurement
Channels (differs)61
Measurement range (differs)60 to 140 dB(A) RMS; linear operating range 65 to 140 dB(A)70 to 140.3 dB(A) RMS (linear operating range)
Linearity range (differs)65 to 140 dB(A)70 to 140.3 dB(A)
Peak range (differs)80 to 143 dB(C)90.0 to 143.3 dB (C or Z weighted)
Frequency range (differs)63 Hz to 8 kHz (octave bands)—
Frequency weightingsA, C, ZA, C, Z
Time weightings (differs)F, SF, S, I
Simultaneous weightings (differs)Yes—
Parameters (differs)Leq/LAVG, LEP,d / LEX,8h / TWA, %Dose and estimated %Dose, Lpeak, sound exposure, ULT duration, SPL max and min, LCeq-LAeq (HML)LXY, LXYmax, LXeq, LXpeak, Lavg, LXIeq, LTM3, LTM5, LAE, LAep,d, LEX,8h, TWA, Dose % (incl. projected), Pa2h, Pa2s, Motion %, time above threshold
DosimetryYesYes
Exchange rates (differs)3 dB, 4 dB, 5 dB3 dB, 5 dB
Analysis
Octave bands (differs)1/1—
Octave band filter class (differs)class 2 (IEC 61260-1:2014)—
Logging and data
Shortest logging interval1 s1 s
Memory (differs)up to 80 h of time history (6 channels); up to 40 measurements; 24 h maximum single measurement64 runs maximum
Hardware
Microphone (differs)—MEMS microphone
Detachable preamplifier (differs)No—
Display (differs)nonenone (multifunction LED status indicator and one action button)
Battery (differs)internal NiMHRechargeable Li-ion 350 mAh; wireless drop-in charger (4 h to 85 %, 6 h to 100 %)
Battery life (differs)20 h16 h
External power (differs)charging dock (3 h from empty)—
Weight (differs)85 g36 g
Dimensions (mm) (differs)66 x 43 x 53 (excluding clips)56 x 32 x 40
IP rating (differs)—IP65
Operating temperature (°C) (differs)-10 to 500 to 40 (< +/-0.5 dB error); -10 to 50 (< +/-0.8 dB error)
Connectivity and software
Connectivity (differs)Bluetooth, USB via charging dockBluetooth
Remote control (differs)doseBadge5 remote control wand; dBLink / MyCirrus app (iOS, Android)OmniWear Noise app (iOS, Android)
Software (differs)NoiseTools, dBLink appOmniWear Noise app

The instruments on their own

Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.