| Specification | NoiseBadge (Model 22)Pulsar Instruments | TSI OmniWear Noise (OW-N-DVE)TSI Quest |
|---|---|---|
| Status | Current | Current |
| Verified on | ||
| Manufacturer list price | GBP 510 | |
| Standards and class | ||
| Standards (differs) | IEC 61252:1993, ANSI S1.25:1991, IEC 60942:2001 class 2 (reader calibrator) | IEC 61252:1997 + A2:2017 (BS EN), ANSI S1.25:1991 (R2024) |
| Recommended calibration interval (differs) | 12 months | — |
| Measurement | ||
| Channels (differs) | 2 | 1 |
| Measurement range (differs) | 70 to 130 dB(A) RMS | 70 to 140.3 dB(A) RMS (linear operating range) |
| Linearity range (differs) | — | 70 to 140.3 dB(A) |
| Peak range (differs) | 120 to 140 dB(C) | 90.0 to 143.3 dB (C or Z weighted) |
| Frequency weightings (differs) | A, C | A, C, Z |
| Time weightings (differs) | S | F, S, I |
| Parameters (differs) | LAeq, LEP,d / LEX,8h, LAE, LCpeak, Lavg, TWA, Dose %, estimated Dose %, exposure Pa2h, 115 dB(A) exceedance | LXY, LXYmax, LXeq, LXpeak, Lavg, LXIeq, LTM3, LTM5, LAE, LAep,d, LEX,8h, TWA, Dose % (incl. projected), Pa2h, Pa2s, Motion %, time above threshold |
| Dosimetry | Yes | Yes |
| Exchange rates (differs) | 3 dB, 4 dB, 5 dB | 3 dB, 5 dB |
| Analysis | ||
| Octave bands (differs) | None | — |
| Reverberation time (differs) | No | — |
| Building acoustics (differs) | No | — |
| Audio recording (differs) | No | — |
| Logging and data | ||
| Shortest logging interval (differs) | 1 min | 1 s |
| Memory (differs) | reader stores up to 93 eight-hour, 64 twelve-hour or 33 twenty-four-hour measurements | 64 runs maximum |
| Hardware | ||
| Microphone (differs) | removable prepolarised electret, 1/2" class 2 | MEMS microphone |
| Detachable preamplifier (differs) | No | — |
| Display (differs) | none on badge (status LED); backlit LCD on reader | none (multifunction LED status indicator and one action button) |
| Battery (differs) | internal NiMH, about 3 h charge; reader 2 x AA or USB | Rechargeable Li-ion 350 mAh; wireless drop-in charger (4 h to 85 %, 6 h to 100 %) |
| Battery life (differs) | 20 h | 16 h |
| Weight (differs) | 45 g | 36 g |
| Dimensions (mm) (differs) | height 38, base diameter 47, microphone apex diameter 13 | 56 x 32 x 40 |
| IP rating (differs) | — | IP65 |
| Operating temperature (°C) (differs) | -10 to 50 | 0 to 40 (< +/-0.5 dB error); -10 to 50 (< +/-0.8 dB error) |
| Connectivity and software | ||
| Connectivity (differs) | infrared to reader, USB 2.0 (reader to PC) | Bluetooth |
| Remote control (differs) | — | OmniWear Noise app (iOS, Android) |
| Software (differs) | AnalyzerPlus | OmniWear Noise app |
The instruments on their own
- NoiseBadge (Model 22) — full record, sources and owner reviews
- TSI OmniWear Noise (OW-N-DVE) — full record, sources and owner reviews
Other comparisons
- dBadge2 vs NoiseBadge (Model 22)
- dBadge2 vs TSI OmniWear Noise (OW-N-DVE)
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs NoiseBadge (Model 22)
- doseBadge5 Personal Noise Dosimeter (CR:120A) vs TSI OmniWear Noise (OW-N-DVE)
- NoiseBadge (Model 22) vs Quest Edge 4+ (EG4P)
- NoiseBadge (Model 22) vs Quest Edge 7 (EG7)
- NoiseBadge (Model 22) vs Quest Edge 8 (EG8)
- Original doseBadge (CR:110A) vs TSI OmniWear Noise (OW-N-DVE)
Want a different combination, or more than two at once? Build your own comparison from any instruments of the same type.